MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/11206721221144656

Медицинская библиотека · European journal of ophthalmology · 2022

Analysis of visual and refractive results after wedge resection for high astigmatism after penetrating keratoplasty in keratoconus.

García de Oteyza Gonzalo, Borasio Edmondo, Ruíz-Santos Maria, Julio Gemma, Barraquer Rafael Ignacio, Alvarez de Toledo Juan

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To analyze visual and refractive results after wedge resection to correct high astigmatism after penetrating keratoplasty (PK) for keratoconus.

SETTING

Cornea Unit of the Centro de Oftalmología Barraquer Barcelona, Spain.

DESIGN

A retrospective quasi-experimental, before and after study.

METHODS

Patients who developed high astigmatism or ectasia in the graft-host junction after PK were treated with wedge resection. The following variables were studied before the surgery, 1-year after and at the final visit: uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refractive and topographic astigmatism and spherical equivalent. Vectorial analysis of the astigmatism changes was performed.

RESULTS

Fifty-one eyes were included with a mean follow-up of 4.19 ± 3.09 years. Mean refractive astigmatism was 11.47 ± 3.57 diopters (D) pre-operatively and 4.79 ± 3.32 D at the final follow-up (p < 0.001). The mean centroid changed from 2.65 ± 11.82 D at 23 degrees preoperatively to 0.35 ± 5.86 D at 127 degrees postoperatively. Concerning spherical equivalent, the mean preoperative value was -3.10 ± 4.15 D and the mean postoperative value was -1.55 ± 3.41 D (p = 0.002). Mean pre-operative and final follow-up UDVA were 1.25 ± 0.27 and 0.84 ± 0.50 (p < 0.001). Mean Pre-op and final follow-up CDVA were 0.27 ± 0.19 and 0.24 ± 0.24.

CONCLUSIONS

Wedge resection is a useful surgical procedure to correct high astigmatism. It is a safe technique with moderate efficacy and may be considered as initial procedure of choice in high astigmatism due to long-term ectasia in the graft-host junction after PK for keratoconus.

Для цитирования: García de Oteyza Gonzalo, Borasio Edmondo, Ruíz-Santos Maria, Julio Gemma, Barraquer Rafael Ignacio, Alvarez de Toledo Juan. Analysis of visual and refractive results after wedge resection for high astigmatism after penetrating keratoplasty in keratoconus.. European journal of ophthalmology. 2022. DOI: 10.1177/11206721221144656.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.