MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/j.jcrs.0000000000001088

Медицинская библиотека · Journal of cataract and refractive surgery · 2022

Accuracy of intraocular lens calculations in eyes with keratoconus.

Vandevenne Magali M S, Webers Valentijn S C, Segers Maartje H M, Berendschot Tos T J M, Zadok David, Dickman Mor M, Nuijts Rudy M M A, Abulafia Adi

Многоцентровое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the prediction accuracy of the Barrett True-K for keratoconus with standard formulas (SRK/T, Barrett Universal II, and Kane) and the Kane keratoconus formula.

SETTING

Shaare Zedek Medical Center, Jerusalem, Israel, and University Eye Clinic, Maastricht, the Netherlands.

DESIGN

Multicenter retrospective case series.

METHODS

Eyes with stable keratoconus undergoing cataract surgery were included. The predicted refractions were calculated for SRK/T, Barrett Universal II, Barrett True-K for keratoconus (predicted and measured), Kane, and Kane adjusted for keratoconus formulas. Primary outcomes were prediction error (PE), absolute error (AE), and percentage of eyes with PE ±0.25 diopters (D), ±0.50 D, and ±1.00 D. Subgroup analyses were performed based on the severity of the keratoconus.

RESULTS

57 eyes were included in the study. The PE was not significantly different from zero for SRK/T, Barrett True-K (predicted and measured), and Kane keratoconus formulas (range 0.09 to 0.22 D, P > .05). The AE of Barrett True-K predicted (median 0.14 D) and Barrett True-K measured (median 0.10 D) were significantly lower from Barrett Universal II (median 0.47 D) and Kane (median 0.50 D), P < .001.

CONCLUSIONS

The Barrett True-K formulas for keratoconus had higher prediction accuracy as compared with new generation formulas and a similar prediction accuracy as compared with the Kane keratoconus formula.

Для цитирования: Vandevenne Magali M S, Webers Valentijn S C, Segers Maartje H M, Berendschot Tos T J M, Zadok David, Dickman Mor M, Nuijts Rudy M M A, Abulafia Adi. Accuracy of intraocular lens calculations in eyes with keratoconus.. Journal of cataract and refractive surgery. 2022. DOI: 10.1097/j.jcrs.0000000000001088.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.