MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/icl.0000000000000940

Медицинская библиотека · Eye & contact lens · 2022

Corneal RGP Contact Lens Fitting Software for Keratoconus Built-In Anterior Segment Optical Coherence Tomography.

Itoi Motohiro, Itoi Motozumi, Harigaya Ayuka, Ishigaki Kaho, Satou Rika, Ueda Eiko

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To assess the performance of the contact lens fitting software built into anterior segment optical coherence tomography (AS-OCT).

METHODS

This retrospective study enrolled patients with keratoconus prescribed with spherical corneal rigid gas-permeable contact lenses based on a contact lens fitting software. Subjects were classified into four subgroups based on corneal morphology: nipple, oval, globus, and marginal type. Software performance was evaluated according to the correlation between the back optical zone radius (BOZR) calculated by the contact lens fitting program and the BOZR of the lens prescribed, and the number of trial lens replacements required.

Results

A total of 340 eyes of 254 patients with a mean age of 40.4 ± 13.6 years were included. The oval type was the most common (61.8%), followed by the nipple type (26.2%). Linear regression analysis revealed a significant correlation between the prescribed and the calculated BOZR in all subgroups (R 2 = 0.92, P < 0.01 for the nipple type; R 2 = 0.76, P < 0.01 for the oval type; R 2 = 0.93, P < 0.01 for the globus type; and R 2 = 0.79, P < 0.01 for the marginal type). Furthermore, the globus type had the highest proportion of cases requiring at least one trial lens replacement (36.3%), followed by the nipple group (27.0%). There were no significant differences among the subgroups ( P = 0.14).

CONCLUSIONS

In conclusion, our findings reveal that the contact lens fitting software built into AS-OCT may be useful for accurate contact lens prescription for any corneal shape.

Для цитирования: Itoi Motohiro, Itoi Motozumi, Harigaya Ayuka, Ishigaki Kaho, Satou Rika, Ueda Eiko. Corneal RGP Contact Lens Fitting Software for Keratoconus Built-In Anterior Segment Optical Coherence Tomography.. Eye & contact lens. 2022. DOI: 10.1097/icl.0000000000000940.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.