MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1056/nejmoa042283

Медицинская библиотека · The New England journal of medicine · 2005

Single-chamber versus dual-chamber pacing for high-grade atrioventricular block.

Toff William D, Camm A John, Skehan J Douglas, United Kingdom Pacing and Cardiovascular Events Trial Investigators

Клиническое исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

In the treatment of atrioventricular block, dual-chamber cardiac pacing is thought to confer a clinical benefit as compared with single-chamber ventricular pacing, but the supporting evidence is mainly from retrospective studies. Uncertainty persists regarding the true benefits of dual-chamber pacing, particularly in the elderly, in whom it is used less often than in younger patients.

METHODS

In a multicenter, randomized, parallel-group trial, 2021 patients 70 years of age or older who were undergoing their first pacemaker implant for high-grade atrioventricular block were randomly assigned to receive a single-chamber ventricular pacemaker (1009 patients) or a dual-chamber pacemaker (1012 patients). In the single-chamber group, patients were randomly assigned to receive either fixed-rate pacing (504 patients) or rate-adaptive pacing (505 patients). The primary outcome was death from all causes. Secondary outcomes included atrial fibrillation, heart failure, and a composite of stroke, transient ischemic attack, or other thromboembolism.

RESULTS

The median follow-up period was 4.6 years for mortality and 3 years for other cardiovascular events. The mean annual mortality rate was 7.2 percent in the single-chamber group and 7.4 percent in the dual-chamber group (hazard ratio, 0.96; 95 percent confidence interval, 0.83 to 1.11). We found no significant differences between the group with single-chamber pacing and that with dual-chamber pacing in the rates of atrial fibrillation, heart failure, or a composite of stroke, transient ischemic attack, or other thromboembolism.

CONCLUSIONS

In elderly patients with high-grade atrioventricular block, the pacing mode does not influence the rate of death from all causes during the first five years or the incidence of cardiovascular events during the first three years after implantation of a pacemaker.

Для цитирования: Toff William D, Camm A John, Skehan J Douglas, United Kingdom Pacing and Cardiovascular Events Trial Investigators. Single-chamber versus dual-chamber pacing for high-grade atrioventricular block.. The New England journal of medicine. 2005. DOI: 10.1056/nejmoa042283.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.