Hu Xiao-Yan, Li Yu-Jie, Shu Xin, Song Ai-Lin, Liang Hao, Sun Yi-Zhu, Wu Xian-Feng, Li Yong-Shuai, Tan Li-Fang, Yang Zhi-Yong, Yang Chun-Yong, Xu Lin-Quan, Chen Yu-Wen, Yi Bin
Аннотация
OBJECTIVE: Non-invasive methods for hemoglobin (Hb) monitoring can provide additional and relatively precise information between invasive measurements of Hb to help doctors' decision-making. We aimed to develop a new method for Hb monitoring based on mask R-CNN and MobileNetV3 with eye images as input.
METHODS: Surgical patients from our center were enrolled. After image acquisition and pre-processing, the eye images, the manually selected palpebral conjunctiva, and features extracted, respectively, from the two kinds of images were used as inputs. A combination of feature engineering and regression, solely MobileNetV3, and a combination of mask R-CNN and MobileNetV3 were applied for model development. The model's performance was evaluated using metrics such as R2, explained variance score (EVS), and mean absolute error (MAE).
RESULTS: A total of 1,065 original images were analyzed. The model's performance based on the combination of mask R-CNN and MobileNetV3 using the eye images achieved an R2, EVS, and MAE of 0.503 (95% CI, 0.499-0.507), 0.518 (95% CI, 0.515-0.522) and 1.6 g/dL (95% CI, 1.6-1.6 g/dL), which was similar to that based on MobileNetV3 using the manually selected palpebral conjunctiva images (R2: 0.509, EVS:0.516, MAE:1.6 g/dL).
CONCLUSION: We developed a new and automatic method for Hb monitoring to help medical staffs' decision-making with high efficiency, especially in cases of disaster rescue, casualty transport, and so on.
METHODS: Surgical patients from our center were enrolled. After image acquisition and pre-processing, the eye images, the manually selected palpebral conjunctiva, and features extracted, respectively, from the two kinds of images were used as inputs. A combination of feature engineering and regression, solely MobileNetV3, and a combination of mask R-CNN and MobileNetV3 were applied for model development. The model's performance was evaluated using metrics such as R2, explained variance score (EVS), and mean absolute error (MAE).
RESULTS: A total of 1,065 original images were analyzed. The model's performance based on the combination of mask R-CNN and MobileNetV3 using the eye images achieved an R2, EVS, and MAE of 0.503 (95% CI, 0.499-0.507), 0.518 (95% CI, 0.515-0.522) and 1.6 g/dL (95% CI, 1.6-1.6 g/dL), which was similar to that based on MobileNetV3 using the manually selected palpebral conjunctiva images (R2: 0.509, EVS:0.516, MAE:1.6 g/dL).