MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12350-015-0097-4

Медицинская библиотека · Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2015

Quantitative iodine-123-metaiodobenzylguanidine (MIBG) SPECT imaging in heart failure with left ventricular systolic dysfunction: Development and validation of automated procedures in conjunction with technetium-99m tetrofosmin myocardial perfusion SPECT.

Clements Ian P, Garcia Ernest V, Chen Ji, Folks Russell D, Butler Javed, Jacobson Arnold F

Оценочное исследованиеСтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

The purpose of this study was to develop and validate new approaches to quantitative MIBG myocardial SPECT imaging in heart failure (HF) subjects.

METHODS AND

RESULTS

Quantitative MIBG myocardial SPECT analysis methods, alone and in conjunction with 99mTc-tetrofosmin perfusion SPECT, were adapted from previously validated techniques for the analysis of SPECT and PET perfusion imaging. To account for underestimation of MIBG defect severity in subjects with global reduction in uptake, a mixed reference database based on planar heart/mediastinum (H/M) ratio categories was used. Extent and severity of voxel-based defects and number of myocardial segments with significant dysinnervation (derived score ≥2) were determined. MIBG/99mTc-tetrofosmin mismatch was quantified using regions with preserved innervation as the reference for scaling 99mTc-tetrofosmin voxel maps. Quantification techniques were tested on studies of 619 ischemic (I) and 319 non-ischemic (NI) HF subjects. Using all analytical techniques, IHF subjects had significantly greater and more severe MIBG SPECT abnormalities compared with NIHF subjects. Innervation/perfusion mismatches were also larger in IHF subjects. Findings were consistent between voxel- and myocardial-segment-based quantitation methods.

CONCLUSIONS

Multiple objective methods for quantitation of MIBG SPECT imaging studies provided internally consistent results for distinguishing the different patterns of uptake between IHF and NIHF subjects.

Для цитирования: Clements Ian P, Garcia Ernest V, Chen Ji, Folks Russell D, Butler Javed, Jacobson Arnold F. Quantitative iodine-123-metaiodobenzylguanidine (MIBG) SPECT imaging in heart failure with left ventricular systolic dysfunction: Development and validation of automated procedures in conjunction with technetium-99m tetrofosmin myocardial perfusion SPECT.. Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology. 2015. DOI: 10.1007/s12350-015-0097-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.