m+Medelevator.RU
← Поиск публикаций
Archives of medical research · 2015

Malignant Pleural Mesothelioma: Accuracy of CT Against Immunohistochemical Test Among the Mexican Population.

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Gopar-Nieto Rodrigo, Aguilar-Madrid Guadalupe, Sotelo-Martínez León, Juárez-Pérez Cuauhtémoc Arturo, Kelly-García Javier, Argote-Greene Luis, Ochoa-Vázquez María Dolores, García-Bazán Eric Marco, Ramírez-Pérez Jorge, Haro-García Luis, Jiménez-Ramírez Carmina, Cabello-López Alejandro

Аннотация

BACKGROUND AND AIMS: Malignant pleural mesothelioma (MPM) is associated with occupational and environmental exposure to asbestos. The incidence is expected to increase as the use of asbestos is not prohibited in many countries, such as in Mexico. We undertook this study to determine sensitivity, specificity, predictive values and likelihood ratios of computed tomography (CT) in a sample from Mexican population with suspected MPM and other pleuropulmonary diseases.

METHODS: CT films of 38 patients suspected of having MPM were analyzed. A single observer was blinded to MPM diagnoses. The frequencies of ten CT findings were identified. A cut-off point of ≥5 CT findings was established to determine high MPM probability. Sensitivity, specificity, predictive values and likelihood ratio of the CT against biopsy using immunohistochemical testing (IHC) for MPM were calculated.

RESULTS: Of the 38 patients, 31 had MPM and seven had lung adenocarcinoma. The five key findings were mediastinal pleural thickening 96.7% (n = 30), nodular pleural thickening 93.3% (n = 29), pleural mass 83.9% (n = 26), diminished lung 70.9% (n = 22) and contracted hemithorax 70.9% (n = 22). Sensitivity 96.8% (83.2-99.4), specificity 85.7% (42.2-97.6), positive likelihood ratio 6.7 (1.1-41.6), and negative likelihood ratio of 0.04 (0.01-0.2) were reported.

CONCLUSIONS: Sensitivity and specificity in this study was greater than previously reported, 96.8% and 85.7 vs. 93.2 and 65.6%, respectively. CT is an easily accessible and useful tool that should be incorporated into the medical education of general physicians to improve MPM diagnosis of suspected cases.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты