m+Medelevator.RU
← Поиск публикаций
Clinics (Sao Paulo, Brazil) · 2010

Glomerular filtration rate measured by (51)Cr-EDTA clearance: Evaluation of captopril-induced changes in hypertensive patients with and without renal artery stenosis.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Chaves Anna Alice Rolim, Buchpiguel Carlos Alberto, Praxedes Jose Nery, Bortolotto Luiz Aparecido, Sapienza Marcelo Tatit

Аннотация

INTRODUCTION: Renal artery stenosis can lead to renovascular hypertension; however, the detection of stenosis alone does not guarantee the presence of renovascular hypertension. Renovascular hypertension depends on activation of the renin-angiotensin system, which can be detected by functional tests such as captopril renal scintigraphy. A method that allows direct measurement of the baseline and post-captopril glomerular filtration rate using chromium-51 labeled ethylenediamine tetraacetic acid ((51)Cr-EDTA) could add valuable information to the investigation of hypertensive patients with renal artery stenosis. The purposes of this study were to create a protocol to measure the baseline and post-captopril glomerular filtration rate using (51)Cr-EDTA, and to verify whether changes in the glomerular filtration rate permit differentiation between hypertensive patients with and without renal artery stenosis.

METHODS: This prospective study included 41 consecutive patients with poorly controlled severe hypertension. All patients had undergone a radiological investigation of renal artery stenosis within the month prior to their inclusion. The patients were divided into two groups: patients with (n=21) and without renal artery stenosis, (n=20). In vitro glomerular filtration rate analysis ((51)Cr-EDTA) and (99m)Tc-DMSA scintigraphy were performed before and after captopril administration in all patients.

RESULTS: The mean baseline glomerular filtration rate was 48.6+/-21.8 ml/kg/1.73 m(2) in the group wuth renal artery stenosis, which was significantly lower than the GFR of 65.1+/-28.7 ml/kg/1.73m(2) in the group without renal artery stenosis (p=0.04). Captopril induced a significant reduction of the glomerular filtration rate in the group with renal artery stenosis (to 32.6+/-14.8 ml/ kg/1.73m(2), p=0.001) and an insignificant change in the group without RAS (to 62.2+/-23.6 ml/kg/1.73m(2), p=0.68). Scintigraphy with technetium-99m dimercapto-succinic acid (DMSA) did not show significant differences in differential renal function from baseline to post-captopril images in either group.

CONCLUSIONS: Captopril induced a decrease in the GFR that could be quantitatively measured with (51)Cr-EDTA. The reduction is more pronounced in hypertensive patients with RAS.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты