Contrast-enhanced MR angiography utilizing parallel acquisition techniques in renal artery stenosis detection.

Slanina Martin, Zizka Jan, Klzo Ludovít, Lojík Miroslav

СтатьяПеревод пока не подготовлен

Аннотация

Significant renal artery stenosis (RAS) is a potentially curable cause of renovascular hypertension and/or renal impairment. It is caused by either atherosclerosis or fibromuscular dysplasia. Correct and timely diagnosis remains a diagnostic challenge. MR angiography (MRA) as a minimally invasive method seems to be suitable for RAS detection, however, its diagnostic value widely differs in the literature (sensitivity 62-100% and specificity 75-100%). The aim of our prospective study was to compare the diagnostic value of contrast-enhanced MRA utilizing parallel acquisition techniques in the detection of significant RAS with digital subtraction angiography (DSA). A total of 78 hypertensive subjects with suspected renal artery stenosis were examined on a 1.5 Tesla MR system using a body array coil. Bolus tracking was used to monitor the arrival of contrast agent to the abdominal aorta. The MRA sequence parameters were as follows: TR 3.7 ms; TE 1.2 ms; flip angle 25 degrees; acquisition time 18s; voxel size 1.1 mm x1.0 mm x 1.1 mm; centric k-space sampling; parallel acquisition technique with acceleration factor of 2 (GRAPPA). Renal artery stenosis of 60% and more was considered hemodynamically significant. The results of MRA were compared to digital subtraction angiography serving as a standard of reference. Sensitivity and specificity of MRA in the detection of hemodynamically significant renal artery stenosis were 90% and 96%, respectively. Prevalence of RAS was 39% in our study population. Contrast-enhanced MRA with high spatial resolution offers sufficient sensitivity and specificity for screening of RAS.

Для цитирования: Slanina Martin, Zizka Jan, Klzo Ludovít, Lojík Miroslav. Contrast-enhanced MR angiography utilizing parallel acquisition techniques in renal artery stenosis detection.. European journal of radiology. 2009. DOI: 10.1016/j.ejrad.2009.07.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.