Correlation and compatibility between surface respiratory electromyography and transesophageal diaphragmatic electromyography measurements during treadmill exercise in stable patients with COPD.

Wu Weiliang, Guan Lili, Li Xiaoying, Lin Lin, Guo Bingpeng, Yang Yuqiong, Liang Zhenyu, Wang Fengyan, Zhou Luqian, Chen Rongchang

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the compatibility and correlation between noninvasive surface respiratory electromyography and invasive transesophageal diaphragmatic electromyography measurements as facilitating indicators of neural respiratory drive (NRD) evaluation during treadmill exercise.

PATIENTS AND

METHODS

Transesophageal diaphragmatic electromyogram activity (EMGdi,es) and surface inspiratory electromyogram (EMG) activity, including surface diaphragmatic EMG activity (EMGdi,sur), surface parasternal intercostal muscle EMG activity (EMGpara), and surface sternocleidomastoid EMG activity (EMGsc), were detected simultaneously during increasing exercise capacity in 20 stable patients with COPD. EMGdi,es, EMGdi,sur, EMGpara, and EMGsc were quantified using the root mean square (RMS) and were represented as RMSdi,es, RMSdi,sur, RMSpara, and RMSsc, respectively.

RESULTS

There was a significant association between EMGdi,es and EMGdi,sur (r=0.966, p<0.01), EMGpara (r=0.967, p<0.01), and EMGsc (r=0.956, p<0.01) in the COPD patients during exercise. Bland-Altman plots showed that the lowest mean bias value was between EMGdi,es and EMGpara compared with the bias values between EMGdi,es and the other two EMG parameters. In comparing the estimation of EMGdi,es, we observed the lowest bias values (-1%) and the lowest limits of agreement values (-10% to -12%). Intraclass correlation coefficient (ICC) between EMGdi,es and EMGdi,sur was 0.978 (p<0.01), between EMGdi,es and EMGpara was 0.980 (p<0.01), and between EMGdi,es and EMGsc was 0.868 (p<0.01).

CONCLUSION

RMSdi,sur, RMSpara, and RMSsc could provide useful physiological markers of NRD in COPD. RMSpara shows the best compatibility and correlation with transesophageal diaphragmatic electromyography during treadmill exercise in stable patients with COPD.

Для цитирования: Wu Weiliang, Guan Lili, Li Xiaoying, Lin Lin, Guo Bingpeng, Yang Yuqiong, Liang Zhenyu, Wang Fengyan, Zhou Luqian, Chen Rongchang. Correlation and compatibility between surface respiratory electromyography and transesophageal diaphragmatic electromyography measurements during treadmill exercise in stable patients with COPD.. International journal of chronic obstructive pulmonary disease. 2017. DOI: 10.2147/copd.s148980.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.