MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcct.2024.08.009

Медицинская библиотека · Journal of cardiovascular computed tomography · 2024

Computed tomography to predict pacemaker need after transcatheter aortic valve replacement.

Verhemel Sarah, Nuis Rutger-Jan, van den Dorpel Mark, Adrichem Rik, de Sá Marchi Mauricio Felippi, Hirsch Alexander, Daemen Joost, Budde Ricardo P J, Van Mieghem Nicolas M

СтатьяОбзорПеревод пока не подготовлен

Аннотация

Transcatheter aortic valve replacement (TAVR) is preferred therapy for elderly patients with severe aortic stenosis (AS) and increasingly used in younger patient populations with good safety and efficacy outcomes. However, cardiac conduction abnormalities remain a frequent complication after TAVR ranging from relative benign interventriculair conduction delays to prognostically relevant left bundle branch block and complete atrio-ventricular (AV) block requiring permanent pacemaker implantation (PPI). Although clinical, procedural and electrocardiographic factors have been identified as predictors of this complication, there is a need for advanced strategies to control the burden of conduction defects particularly as TAVR shifts towards younger populations. This state of the art review highlights the value of ECG-synchronized computed tomographic angiography (CTA) evaluation of the aortic root to better understand and manage conduction problems post-TAVR. An update on CTA derived anatomic features related to conduction issues is provided and complemented with computational framework modelling. This CTA-derived 3-dimensional anatomical reconstruction tool generates patient-specific TAVR simulations enabling operators to adapt procedural strategy and implantation technique to mitigate conduction abnormality risks.

Для цитирования: Verhemel Sarah, Nuis Rutger-Jan, van den Dorpel Mark, Adrichem Rik, de Sá Marchi Mauricio Felippi, Hirsch Alexander, Daemen Joost, Budde Ricardo P J, Van Mieghem Nicolas M. Computed tomography to predict pacemaker need after transcatheter aortic valve replacement.. Journal of cardiovascular computed tomography. 2024. DOI: 10.1016/j.jcct.2024.08.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.