Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2024
Mid-term clinical outcomes of left bundle branch area pacing compared to accurate right ventricular septal pacing.
СтатьяНаблюдательное исследованиеСравнительное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Okubo Yousaku, Sakai Takumi, Miyamoto Shogo, Uotani Yukimi, Oguri Naoto, Furutani Motoki, Miyauchi Shunsuke, Okamura Sho, Tokuyama Takehito, Nakano Yukiko
Аннотация
BACKGROUND: Although left bundle branch area pacing (LBBAP) reportedly results in fewer adverse outcomes after implantation than conventional stylet-guided right ventricular septal pacing (RVSP), previous studies have not compared LBBAP with accurate RVSP using a delivery catheter. The aim of this study was to compare clinical outcomes between LBBAP and accurate RVSP among patients with atrioventricular block (AVB).
METHODS: This single-center observational study enrolled 160 patients requiring RV pacing due to symptomatic AVB between September 2018 and December 2021. Primary composite outcomes included all-cause death, hospitalization due to heart failure (HF), and upgrading to biventricular pacing. Secondary composite outcomes included any procedural and postprocedural complications.
RESULTS: Overall, 160 patients were analyzed (LBBAP, n = 81; RVSP, n = 79). No significant differences in baseline characteristics were observed between the two groups. The RV pacing burden at 1 year after implantation was 90.8% ± 20.4% and 86.2% ± 22.6%, respectively (p = 0.21). During a mean follow-up of 840 ± 369 days, the incidence of the primary outcome was significantly lower with LBBAP (4.9%) compared to RVSP (22.8%) (Log-rank p = 0.02). There was no significant difference in the incidence of the secondary outcome between the two groups (3.7% vs. 5.1%, p = 0.65). In the multivariate analysis, baseline QRS duration, RV pacing burden, and LBBAP were independently associated with the primary outcome (baseline QRS duration: hazard ratio [HR], 1.01; 95% confidence interval [CI], 1.00-1.02; p < 0.001; RV pacing burden: HR, 1.01; 95% CI, 1.00-1.02; p < 0.001; LBBAP: HR, 0.45; 95% CI, 0.31-0.64; p < 0.001).
CONCLUSION: In patients requiring frequent RV pacing, LBBAP was associated with reduced adverse clinical outcome compared to accurate RVSP using a delivery catheter.
METHODS: This single-center observational study enrolled 160 patients requiring RV pacing due to symptomatic AVB between September 2018 and December 2021. Primary composite outcomes included all-cause death, hospitalization due to heart failure (HF), and upgrading to biventricular pacing. Secondary composite outcomes included any procedural and postprocedural complications.
RESULTS: Overall, 160 patients were analyzed (LBBAP, n = 81; RVSP, n = 79). No significant differences in baseline characteristics were observed between the two groups. The RV pacing burden at 1 year after implantation was 90.8% ± 20.4% and 86.2% ± 22.6%, respectively (p = 0.21). During a mean follow-up of 840 ± 369 days, the incidence of the primary outcome was significantly lower with LBBAP (4.9%) compared to RVSP (22.8%) (Log-rank p = 0.02). There was no significant difference in the incidence of the secondary outcome between the two groups (3.7% vs. 5.1%, p = 0.65). In the multivariate analysis, baseline QRS duration, RV pacing burden, and LBBAP were independently associated with the primary outcome (baseline QRS duration: hazard ratio [HR], 1.01; 95% confidence interval [CI], 1.00-1.02; p < 0.001; RV pacing burden: HR, 1.01; 95% CI, 1.00-1.02; p < 0.001; LBBAP: HR, 0.45; 95% CI, 0.31-0.64; p < 0.001).
CONCLUSION: In patients requiring frequent RV pacing, LBBAP was associated with reduced adverse clinical outcome compared to accurate RVSP using a delivery catheter.