European journal of heart failure · 2024

Predictors of the efficacy of His bundle pacing in patients with a prolonged PR interval: A stratified analysis of the HOPE-HF randomized controlled trial.

СтатьяРандомизированное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Keene Daniel, Kaza Nandita, Srinivasan Divya, Ali Nadine, Tanner Mark, Foley Paul, Chandrasekaran Badri, Moore Philip, Adhya Shaumik, Qureshi Norman, Muthumala Amal, Lane Rebecca, Rinaldi Aldo, Agarwal Sharad, Leyva Francisco, Behar Jonathan, Bassi Sukh, Ng Andre, Scott Paul, Prasad Rachana, Swinburn Jon, Tomson Joseph, Sethi Amarjit, Shah Jaymin, Lim Phang Boon, Kyriacou Andreas, Thomas Dewi, Chuen Jenny, Kamdar Ravi, Kanagaratnam Prapa, Mariveles Myril, Johnson Nicholas, Falaschetti Emanuela, Howard James P, Arnold Ahran, Cleland John G F, Francis Darrel P, Whinnett Zachary, Shun-Shin Matthew

Аннотация

AIMS: The randomized, double-blind, placebo-controlled HOPE-HF trial assessed the benefit of atrio-ventricular (AV) delay optimization delivered using His bundle pacing. It recruited patients with left ventricular ejection fraction ≤40%, PR interval ≥200 ms, and baseline QRS ≤140 ms or right bundle branch block. Overall, there was no significant increase in peak oxygen uptake (VO2max) but there was significant improvement in heart failure specific quality of life. In this pre-specified secondary analysis, we evaluated the impact of baseline PR interval, echocardiographic E-A fusion, and the magnitude of acute high-precision haemodynamic response to pacing, on outcomes.

METHODS AND RESULTS: All 167 randomized participants underwent measurement of PR interval, acute haemodynamic response at optimized AV delay, and assessment of presence of E-A fusion. We tested the impact of these baseline parameters using a Bayesian ordinal model on VO2max, quality of life and activity measures. There was strong evidence of a beneficial interaction between the baseline acute haemodynamic response and the blinded benefit of pacing for VO2 (Pr 99.9%), Minnesota Living With Heart Failure (MLWHF) (Pr 99.8%), MLWHF physical limitation score (Pr 98.9%), EQ-5D visual analogue scale (Pr 99.6%), and exercise time (Pr 99.4%). The baseline PR interval and the presence of baseline E-A fusion did not have this reliable ability to predict the clinical benefit of pacing over placebo across multiple endpoints.

CONCLUSIONS: In the HOPE-HF trial, the acute haemodynamic response to pacing reliably identified patients who obtained clinical benefit. Patients with a long PR interval (≥200 ms) and left ventricular impairment who obtained acute haemodynamic improvement with AV-optimized His bundle pacing were likely to obtain clinical benefit, consistent across multiple endpoints. Importantly, this gradation can be reliably tested for before randomization, but does require high-precision AV-optimized haemodynamic assessment to be performed.