MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jfma.2024.03.002

Медицинская библиотека · Journal of the Formosan Medical Association = Taiwan yi zhi · 2024

Selective placement of novel compression suture technique to reduce pacemaker implantation rate following surgical aortic valve replacement with rapid deployment INTUITY valve.

Yang Kelvin Jeason, Wang Chih-Hsien, Tsai Hsiao-En, Yu Sheng-Pin, Chen Yih-Sharng, Chi Nai-Hsin

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

The use of RDV in SAVR is associated with risk of conduction abnormality requiring PPM implantation, when compared to conventional bioprosthetic valves. We aimed to evaluate the outcome after selective placement of annular compression sutures during surgical aortic valve replacement (SAVR) using Intuity rapid deployment valve (RDV).

METHODS

This is a retrospective study of prospectively enrolled patients receiving SAVR using Intuity RDV. Selective placement of commissural compression suture was assessed for all patients based on their annular morphology. Outcomes including operative mortality, rate of pacemaker rate, paravalvular leak and change in trans-valvular pressure gradient were analyzed.

RESULTS

56 consecutive patients underwent SAVR with the INTUITY RDV at our institution from January 2020 to November 2021. The Mean age of our cohort was 69.9 ± 10.6 years with a EuroSCORE II of 3.4 ± 2.4%. 28.6% (16/56) of patients had notable conduction abnormalities pre-operatively, which included atrial fibrillation and left/right bundle branch block. Compression sutures were selectively applied in 19/56 (33.9%) patients. Of which, 13 were bicuspid aortic valve. Post-operatively, we observed no conduction abnormality requiring PPM implantation. In addition, only 3 of the 56 (5.4%) had any degree of paravalvular leak on post-operative echocardiography (all ≤ mild). The mean reduction in trans-valvular gradient was 29.9 mmHg and the mean pressure gradient at 1 month and 1 year follow-up were 9.3 ± 3.6 mmHg and 10.2 ± 4.1 mmHg, respectively.

CONCLUSION

Selective placement of compression suture helps to avoid unnecessary oversizing, which may reduce the risk of paravalvular leak and post-operative PPM implantation.

Для цитирования: Yang Kelvin Jeason, Wang Chih-Hsien, Tsai Hsiao-En, Yu Sheng-Pin, Chen Yih-Sharng, Chi Nai-Hsin. Selective placement of novel compression suture technique to reduce pacemaker implantation rate following surgical aortic valve replacement with rapid deployment INTUITY valve.. Journal of the Formosan Medical Association = Taiwan yi zhi. 2024. DOI: 10.1016/j.jfma.2024.03.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.