MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0294221

Медицинская библиотека · PloS one · 2024

Clinical value of the fibrosis-4 index in predicting mortality in patients with right ventricular pacing.

Inoue Naoya, Morikawa Shuji, Ogane Takashi, Hiramatsu Takehiro, Murohara Toyoaki

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The fibrosis-4 (FIB-4) index has attracted attention as a predictive factor for cardiovascular events and mortality in patients with heart disease. However, its clinical value in patients with implanted pacemakers remains unclear.

METHODS

This study included patients who underwent pacemaker implantation. The FIB-4 index was calculated based on blood tests performed during the procedure. The primary outcome was all-cause mortality, and the secondary outcomes included cardiovascular death, non-cardiovascular death, and major adverse cardiovascular events (MACE; composite of cardiovascular death, heart failure hospitalization, non-fatal myocardial infarction, and non-fatal stroke). The FIB-4 index was stratified into tertiles. Between-group comparisons were performed using log-rank tests and multivariate analysis using Cox proportional hazards. The predictive accuracy and cut-off value of the FIB-4 index were calculated from the receiver operating characteristic curve for all-cause mortality. Finally, based on the calculated cut-off values, the patients were divided into two groups for outcome validation and subgroup analysis.

RESULTS

This study included 201 participants, of whom 38 experienced death during the observation period (median: 1097 days). All-cause mortality, non-cardiovascular death, and MACE differed significantly between groups stratified by the FIB-4 index tertiles (log-rank test: P<0.001, P<0.001, and P = 0.045, respectively). Using Cox proportional hazards analysis, the unadjusted hazard ratio was 4.75 (95% confidence interval [CI]: 2.05-11.0, P<0.001) for Tertile 3 compared to Tertile 1. After adjustment for confounding factors, including sex, the presence or absence of left bundle branch block at baseline, QRS duration during pacing, and pacing rate at the last check, the hazard ratio was 4.79 (95% CI: 2.04-11.2, P<0.001). The cut-off value of the FIB-4 index was 3.75 (area under the curve: 0.72, 95% CI: 0.62-0.82).

CONCLUSIONS

In patients with pacemakers, the FIB-4 index may be a predictor of early all-cause mortality, with a cut-off value of 3.75.

Для цитирования: Inoue Naoya, Morikawa Shuji, Ogane Takashi, Hiramatsu Takehiro, Murohara Toyoaki. Clinical value of the fibrosis-4 index in predicting mortality in patients with right ventricular pacing.. PloS one. 2024. DOI: 10.1371/journal.pone.0294221.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.