MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/s25123619

Медицинская библиотека · Sensors (Basel, Switzerland) · 2025

A Superpixel-Based Algorithm for Detecting Optical Density Changes in Choroidal Optical Coherence Tomography Images of Diabetic Patients.

Otin Sofia, Mallen-Gracia Victor, Perez-Maña Luis, Ávila Francisco J, Garcia-Martin Elena

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

This study explored the diagnostic potential of image-processing analysis in optical coherence tomography (OCT) images to detect systemic vascular changes in individuals with systemic diseases.

METHODS

Ocular OCT images from two cohorts diabetic patients and healthy control subjects were analyzed. A novel Superpixel Segmentation (SpS) algorithm was used to process these images and extract optical image density information from ocular vascular tissue. The algorithm was applied to isolate the choroid layer for analysis of its optical properties. The procedure was performed by separate examiners, and both inter- and intra-observer repeatability were assessed. Choroidal area (CA) and choroidal optical image density (COID) metrics were used to assess structural changes in the vascular tissue and predict alterations in the choroidal parameters.

RESULTS

A total of 110 diabetic patient eye images and 92 healthy control images were processed. The results showed significant differences in CA and COID between diabetic and healthy eyes, indicating that these parameters could serve as valuable biomarkers for early vascular damage.

CONCLUSIONS

The use of the SpS algorithm on OCT B-scan images allows for the identification of new parameters linked to ocular vascular damage. These findings suggest that digital image-processing techniques can reveal differences in vascular tissue, offering potential new indicators of pathology.

Для цитирования: Otin Sofia, Mallen-Gracia Victor, Perez-Maña Luis, Ávila Francisco J, Garcia-Martin Elena. A Superpixel-Based Algorithm for Detecting Optical Density Changes in Choroidal Optical Coherence Tomography Images of Diabetic Patients.. Sensors (Basel, Switzerland). 2025. DOI: 10.3390/s25123619.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.