MedElevator Войти в исследования
← Поиск публикаций

DOI 10.21037/qims-23-1091

Медицинская библиотека · Quantitative imaging in medicine and surgery · 2023

Analysis of false-positive and false-negative results in 99mTc-MIBI SPECT/CT parathyroid imaging.

Liu Yan, Yang Lulu, Xu Hui, Yang Yiyuan, Liang Yiqian, Yang Aimin, Tang Xiaojiang, Lei Shengkai, Christakis Ioannis, Jitpratoom Pornpeera, Xue Jianjun

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Exact preoperative localization is desirable to perform minimally invasive parathyroidectomy for hyperparathyroidism (HPT). This study aimed to evaluate the diagnostic values of 99mTc-methoxyisobutylisonitrile (99mTc-MIBI) single photon emission computed tomography/computed tomography (SPECT/CT) of parathyroid glands by analyzing the relationship between lesion weight and false-negative (FN) results, as well as to explain the possible reason.

METHODS

The data from 314 patients with suspected HPT who underwent 99mTc-MIBI SPECT/CT parathyroid imaging between 2011 and 2022 were retrospectively evaluated. The sensitivity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of parathyroid 99mTc-MIBI SPECT/CT were calculated, and the false-positive (FP) and FN findings were analyzed.

RESULTS

Accurate localization by 99mTc-MIBI SPECT/CT was significantly associated with the parathyroid hormone (PTH) level. The 99mTc-MIBI SPECT/CT for diagnosis/lesion location reached a sensitivity of 84.6%/56.8%, a PPV of 97.3%/98.4%, an NPV of only 23.7%/4.18%, and an accuracy of 83.4%/57.1%, respectively. The largest diameter, shortest diameter, and lesion volume were lower in the FN group than in the TP group. A total of 7 FP cases were found, including 2 cases of thyroid nodules, 4 cases of thyroid tissue, and 1 case of hibernoma. A total of 45 FN patients, including 321 FN lesions, were confirmed, of which parathyroid hyperplasia accounted for 97.8%. Lesion weights greater than 20 µg were able to be detected, but lightweight lesions less than 100 mg were the principal source of FN results, accounting for approximately 39.3%. With lesion weights 0-100, 101-300, 301-1,000, and >1,000 mg, the FN rate was 70.8% (126/178), 51.8% (103/199), 34.6% (81/234), and 8.33% (11/132), respectively.

CONCLUSIONS

99mTc-MIBI SPECT/CT parathyroid imaging provides good sensitivity and high specificity in HPT location. Correct localization by 99mTc-MIBI SPECT/CT correlates positively with lesion weight and PTH levels. The smaller the lesion, the higher the FN rate in 99mTc-MIBI SPECT/CT parathyroid imaging, and lesions weighing less than 100 mg are the main source of FN results in 99mTc-MIBI SPECT/CT parathyroid imaging.

Для цитирования: Liu Yan, Yang Lulu, Xu Hui, Yang Yiyuan, Liang Yiqian, Yang Aimin, Tang Xiaojiang, Lei Shengkai, Christakis Ioannis, Jitpratoom Pornpeera, Xue Jianjun. Analysis of false-positive and false-negative results in 99mTc-MIBI SPECT/CT parathyroid imaging.. Quantitative imaging in medicine and surgery. 2023. DOI: 10.21037/qims-23-1091.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.