m+Medelevator.RU
← Поиск публикаций
Journal of paediatrics and child health · 2023

Room air versus 100% oxygen for delivery room resuscitation of preterm neonates in low resource settings: A randomised, blinded, controlled trial.

Рандомизированное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Liyakat Nishath A, Kumar Praveen, Sundaram Venkataseshan

Аннотация

AIM: International Liaison Committee on Resuscitation (ILCOR-2020) report recommend starting delivery room resuscitation of all preterm neonates of <35 weeks' gestation with 21-30% oxygen. However, the correct initial oxygen concentration for resuscitation of preterm neonates in delivery room is inconclusive. In this blinded, randomised, controlled trial, we compared room air with 100% oxygen for oxidative stress and clinical outcomes in delivery room resuscitation of preterm neonates.

METHODS: Preterm neonates 28-33 weeks' gestation requiring positive pressure ventilation at birth were randomly allocated to room air or 100% oxygen. Investigators, outcome assessors and data analysts were blinded. Rescue 100% oxygen was used whenever trial gas failed (need for positive pressure ventilation >60 s or chest compression).

PRIMARY OUTCOME: Plasma 8-isoprostane levels at 4 h of age.

SECONDARY OUTCOMES: mortality by discharge, bronchopulmonary dysplasia, retinopathy of prematurity and neurological status at 40 weeks post-menstrual age. All subjects were followed till discharge. Intention to treat analysis was carried out.

RESULTS: A total of 124 neonates were randomised to room air (n = 59) or 100% oxygen (n = 65). Isoprostane level at 4 h was similar in both the groups (median (interquartile range): 280 (180-430) vs. 250 (173-360) pg/mL, P = 0.47). No difference was observed in mortality and other clinical outcomes. Room air group had higher treatment failures (27 (46%) vs. 16 (25%); relative risk (RR) 1.9 (1.1-3.1)) and took longer time to establish regular respiration (230 ± 231 vs. 182 ± 261, mean difference = 48 (40, 136) seconds).

CONCLUSIONS: In preterm neonates 28-33 weeks' gestation requiring resuscitation in the delivery room, room air (21%) is not the correct concentration to initiate resuscitation. Larger controlled trials involving multiple centres in low- and middle-income countries are immediately required for a conclusive answer.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты