Physiotherapy theory and practice · 2022
Validation and reproducibility of the Glittre activities of the daily living test for evaluation of functional capacity after a stroke.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Costa Glaucio Carneiro, Dal Corso Simone, Silva Soraia Micaela, Teodosio Amanda da Conceição, Simada Pelosi Rosane, Elício Virginia Do Carmo, José Anderson, Dias Raphael Ritti, Ferrari Corrêa João Carlos, Corrêa Fernanda Ishida
Аннотация
METHODS: Thirty patients with hemiparesis stemming from a stroke and 20 healthy peers were evaluated. Reproducibility was determined using the intraclass correlation coefficient (ICC), standard measurement error (SME), minimum detectable change (MDC), and Bland-Altman analysis. For construct validity, the Glittre ADL test was correlated with the Six-Minute Walk Test (6MWT), Timed Up and Go Test (TUG), and Functional Independence Measure (FIM), and analyzed based on convergent validity and the comparison of known groups (stroke survivors and healthy peers).
RESULTS: Intra- and inter-observer reliability were excellent (ICC3,1 = 0.98; 0.96, respectively). Intra-observer SME ranged from 0.27 to 0.31 minutes and inter-observer SME was 0.45 minutes. Intra-observer MDC ranged from 1.44 to 1.54 minutes and inter-observer MDC was 1.86 minutes. Strong statistically significant correlations were found between time on the Glittre ADL test and time on the 6MWT (rh = -0.91; p < .001) and TUG test (rh = 0.82; p < .001), whereas a moderate correlation was found with the FIM (rh = -0.47; p < .008).
CONCLUSIONS: The Glittre ADL test is valid for assessing functional capacity in stroke patients. It demonstrated good convergent and construct validity and excellent intra- and inter-observer reproducibility.
RESULTS: Intra- and inter-observer reliability were excellent (ICC3,1 = 0.98; 0.96, respectively). Intra-observer SME ranged from 0.27 to 0.31 minutes and inter-observer SME was 0.45 minutes. Intra-observer MDC ranged from 1.44 to 1.54 minutes and inter-observer MDC was 1.86 minutes. Strong statistically significant correlations were found between time on the Glittre ADL test and time on the 6MWT (rh = -0.91; p < .001) and TUG test (rh = 0.82; p < .001), whereas a moderate correlation was found with the FIM (rh = -0.47; p < .008).
CONCLUSIONS: The Glittre ADL test is valid for assessing functional capacity in stroke patients. It demonstrated good convergent and construct validity and excellent intra- and inter-observer reproducibility.