MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/1748-717x-7-199

Медицинская библиотека · Radiation oncology (London, England) · 2012

Comparative analysis of dosimetric parameters of three different radiation techniques for patients with Graves' ophthalmopathy treated with retro-orbital irradiation.

Lee Victor H F, Ng Sherry C Y, Choi Cheuk Wai, Luk Mai Yee, Leung To Wai, Au Gordon K H, Kwong Dora L W

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

We would like to investigate the if IMRT produced better target coverage and dose sparing to adjacent normal structures as compared with 3-dimensional conformal radiotherapy (3DCRT) and lateral opposing fields (LOF) for patients with Graves' ophthalmopathy treated with retro-orbital irradiation.

METHODS

Ten consecutive patients diagnosed with Graves' ophthalmopathy were prospectively recruited into this study. An individual IMRT, 3DCRT and LOF plan was created for each patient. Conformity index (CI), homogeneity index (HI) and other dosimetric parameters of the targets and organs-at-risk (OAR) generated by IMRT were compared with the other two techniques.

RESULTS

Mann-Whitney U test demonstrated that CI generated by IMRT was superior to that produced by 3DCRT and LOF (p=0.005 for both respectively). Similarly HI with IMRT was proven better than 3DCRT (p=0.007) and LOF (p=0.005). IMRT gave rise to better dose sparing to some OARs including globes, lenses and optic nerves as compared with 3DCRT but not with LOF.

CONCLUSIONS

IMRT, as compared with 3DCRT and LOF, was found to have a better target coverage, conformity and homogeneity and dose sparing to some surrounding structures, despite a slight increase but clinically negligible dose to other structures. Dosimetrically it might be a preferred treatment technique and a longer follow up is warranted to establish its role in routine clinical use.

Для цитирования: Lee Victor H F, Ng Sherry C Y, Choi Cheuk Wai, Luk Mai Yee, Leung To Wai, Au Gordon K H, Kwong Dora L W. Comparative analysis of dosimetric parameters of three different radiation techniques for patients with Graves' ophthalmopathy treated with retro-orbital irradiation.. Radiation oncology (London, England). 2012. DOI: 10.1186/1748-717x-7-199.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.