Discovery medicine · 2024
Interferon-Gamma Release Assay Combined with Renal Indicators to Reduce the False-Negativity of Latent Tuberculosis Infection in End-Stage Renal Disease with Hemodialysis Patients.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Xuan Xianglan, Park Heechul, Kang Yun-Jeong, Jung Minju, Kim Sohyeong, Park Yujin, Lee Eun Ju, Kim Ye Na, Park Ji Young, Chang Hee-Kyung, Kim Jungho, Lim Jaewon, Kim Sunghyun
Аннотация
BACKGROUND: Tuberculosis (TB) is still the main cause of mortality due to a single transfectant, Mycobacterium tuberculosis (MTB). Latent tuberculosis infection (LTBI) is a condition characterized by the presence of tuberculosis (TB) that is not clinically apparent but nonetheless shows a sustained response to MTB. Presently, tuberculin skin test (TST) and interferon gamma (IFN-γ) release assays (IGRAs) are mainly used to detect LTBI via cell-mediated immunity of T-cells. For people with end-stage renal disease (ESRD), the diagnosis of patients infected with MTB is difficult because of T-cell dysfunction. To get more accurate diagnosis results of LTBI, it must compensate for the deficiency of IGRA tests.
METHODS: Sixty-seven hemodialysis (HD) patients and 96 non-HD patients were enrolled in this study and the study population is continuously included. IFN-γ levels were measured by the QuantiFERON-TB Gold In-Tube (QFT-GIT) test. Kidney function indicators, blood urea nitrogen (BUN), serum creatinine (Cr), and estimated glomerular filtration rate (eGFR) were used to compensate for the declined IFN-γ levels in the IGRA test.
RESULTS: In individuals who were previously undetected, the results of compensation with serum Cr increased by 10.81%, allowing for about 28% more detection, and compensation with eGFR increased by 5.41%, allowing for approximately 14% more detectable potential among them and employing both of them could enhance the prior shortcomings of IGRA tests. when both are used, the maximum compensation results show a sensitivity increase rate of 8.81%, and approximately 23% of patients who were previously undetectable may be found.
CONCLUSION: Therefore, the renal function markers which are routine tests for HD patients to compensate for the deficiency of IGRA tests could increase the accuracy of LTBI diagnosis.
METHODS: Sixty-seven hemodialysis (HD) patients and 96 non-HD patients were enrolled in this study and the study population is continuously included. IFN-γ levels were measured by the QuantiFERON-TB Gold In-Tube (QFT-GIT) test. Kidney function indicators, blood urea nitrogen (BUN), serum creatinine (Cr), and estimated glomerular filtration rate (eGFR) were used to compensate for the declined IFN-γ levels in the IGRA test.
RESULTS: In individuals who were previously undetected, the results of compensation with serum Cr increased by 10.81%, allowing for about 28% more detection, and compensation with eGFR increased by 5.41%, allowing for approximately 14% more detectable potential among them and employing both of them could enhance the prior shortcomings of IGRA tests. when both are used, the maximum compensation results show a sensitivity increase rate of 8.81%, and approximately 23% of patients who were previously undetectable may be found.
CONCLUSION: Therefore, the renal function markers which are routine tests for HD patients to compensate for the deficiency of IGRA tests could increase the accuracy of LTBI diagnosis.