DOI 10.24976/discov.med.202436184.93
Interferon-Gamma Release Assay Combined with Renal Indicators to Reduce the False-Negativity of Latent Tuberculosis Infection in End-Stage Renal Disease with Hemodialysis Patients.
Аннотация
BACKGROUND
Tuberculosis (TB) is still the main cause of mortality due to a single transfectant, Mycobacterium tuberculosis (MTB). Latent tuberculosis infection (LTBI) is a condition characterized by the presence of tuberculosis (TB) that is not clinically apparent but nonetheless shows a sustained response to MTB. Presently, tuberculin skin test (TST) and interferon gamma (IFN-γ) release assays (IGRAs) are mainly used to detect LTBI via cell-mediated immunity of T-cells. For people with end-stage renal disease (ESRD), the diagnosis of patients infected with MTB is difficult because of T-cell dysfunction. To get more accurate diagnosis results of LTBI, it must compensate for the deficiency of IGRA tests.
METHODS
Sixty-seven hemodialysis (HD) patients and 96 non-HD patients were enrolled in this study and the study population is continuously included. IFN-γ levels were measured by the QuantiFERON-TB Gold In-Tube (QFT-GIT) test. Kidney function indicators, blood urea nitrogen (BUN), serum creatinine (Cr), and estimated glomerular filtration rate (eGFR) were used to compensate for the declined IFN-γ levels in the IGRA test.
RESULTS
In individuals who were previously undetected, the results of compensation with serum Cr increased by 10.81%, allowing for about 28% more detection, and compensation with eGFR increased by 5.41%, allowing for approximately 14% more detectable potential among them and employing both of them could enhance the prior shortcomings of IGRA tests. when both are used, the maximum compensation results show a sensitivity increase rate of 8.81%, and approximately 23% of patients who were previously undetectable may be found.
CONCLUSION
Therefore, the renal function markers which are routine tests for HD patients to compensate for the deficiency of IGRA tests could increase the accuracy of LTBI diagnosis.