DOI 10.1016/j.pdpdt.2025.105216

Медицинская библиотека · Photodiagnosis and photodynamic therapy · 2025

Changes of refraction and visual quality after ray-tracing guided FS-LASIK in Chinese high myopia versus low-to-moderate myopia.

Huang Yuyan, Li Jiayu, Zhang Fengju, Song Yanzheng, Xu Yushan, Zhang Yixin, Yang Yuxin, Zhang Linlu, Wen Jie

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To investigate the changes of refraction and visual quality after ray-tracing guided femtosecond laser-assisted in situ keratomileusis (FS-LASIK) in Chinese high myopia (HM) compared to that of low-to-moderate myopia (LM).

METHODS

38 eyes in the HM group and 34 eyes in the LM group were evaluated 6 months after ray-tracing guided FS-LASIK. The InnovEyes Sightmap device was used to acquire high-order aberrations and generate individualized 3D eye model ablation profile. The Quality of Vision and Ocular Surface Disease Index questionnaires were used to evaluate the subjective visual quality and dry eye syndrome, respectively.

RESULTS

In the HM group, postoperative MRSE demonstrated an alternation from 0.19 ± 0.53 D at 1 month to 0.06 ± 0.35 D at 6 months (P = 0.029). Similar tendency of MRSE was observed in the LM group, changing from 0.23 ± 0.33 D to 0.04 ± 0.32 D (P < 0.001). Visual symptoms gradually alleviated with time, especially the frequency and the severity of blurred vision (P = 0.007 and 0.018). None of the participants reported the bothersome of halos 6 months postoperatively. 80.95% of participants reported no dry eye discomfort 6 months after surgery. No correlations were found between preoperative MRSE and the postoperative subjective visual symptoms (all P > 0.050). Greater spherical aberration (SA) decrease at 6-mm pupil size was correlated to lower level of starburst (coef = 2.40, P = 0.046).

CONCLUSIONS

Ray-tracing guided FS-LASIK demonstrated comparable efficacy and visual quality in HM compared to LM. The decline in SA may contributed to the relief of subjective visual complaints, especially the starbursts in high myopia.

Для цитирования: Huang Yuyan, Li Jiayu, Zhang Fengju, Song Yanzheng, Xu Yushan, Zhang Yixin, Yang Yuxin, Zhang Linlu, Wen Jie. Changes of refraction and visual quality after ray-tracing guided FS-LASIK in Chinese high myopia versus low-to-moderate myopia.. Photodiagnosis and photodynamic therapy. 2025. DOI: 10.1016/j.pdpdt.2025.105216.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.