MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajo.2025.09.010

Медицинская библиотека · American journal of ophthalmology · 2025

Intraocular Lens Power Calculations in Posthyperopic Laser Vision Correction Eyes: Comparing Legacy and New No-History Formulas.

Suraneni Sanjana, Bleeker Adam R, Anter Abdelrahman M, Leal Sebastian, Murphy David A, Riaz Kamran M, Cooke David L, Tonk Rahul S

СтатьяСравнительное исследованиеПоддержка исследования: вне правительства СШАПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the refractive accuracy of legacy and new postrefractive formulas in eyes with previous hyperopic laser vision correction (H-LVC).

DESIGN

Retrospective cohort study.

SUBJECTS: Total 153 eyes (109 patients) with previous H-LVC that underwent cataract surgery between 2019 and 2023.

METHODS

An SS-OCT biometer was used to obtain biometric measurements, including standard (K), posterior (PK), and total keratometry (TK) values. Refractive prediction errors were calculated and compared for two legacy H-LVC formulas using K values, six new H-LVC formulas using K values, and four new H-LVC formulas using PK or TK values.

MAIN OUTCOME MEASURES: All formulas were ranked by root mean square error (RMSE) and percentage of eyes with prediction errors within ±0.50 D. Heteroscedastic (RMSE) testing was used to evaluate relative formula performance.

RESULTS

When ranked by RMSE, newer formulas ranked higher than legacy formulas, and new formulas with PK/TK values ranked higher than versions without PK/TK values. Using heteroscedastic (RMSE) testing, Barrett True K NH-K was superior to Shammas PHL (P < .001). Shammas-Cooke (Kpost = 0.8977 x K -0.2976 x AL + 11.7149) and K6-TK were superior to their prior H-LVC versions (Shammas-PHL and K6-K, respectively) (P < .05).

CONCLUSIONS

The top-ranking formulas (Barrett True K-TK, K6-TK, and EVO 2.0-PK) were all new H-LVC formulas. Formula performance may variably improve with PK/TK values. When PK/TK values are unavailable, EVO 2.0-K, Barrett True K NH-K, and Pearl DGS may be the most reliable formulas.

Для цитирования: Suraneni Sanjana, Bleeker Adam R, Anter Abdelrahman M, Leal Sebastian, Murphy David A, Riaz Kamran M, Cooke David L, Tonk Rahul S. Intraocular Lens Power Calculations in Posthyperopic Laser Vision Correction Eyes: Comparing Legacy and New No-History Formulas.. American journal of ophthalmology. 2025. DOI: 10.1016/j.ajo.2025.09.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.