m+Medelevator.RU
← Поиск публикаций
JACC. Cardiovascular imaging · 2022

Clinical Applications of FDG-PET Scan in Arrhythmic Myocarditis.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Peretto Giovanni, Busnardo Elena, Ferro Paola, Palmisano Anna, Vignale Davide, Esposito Antonio, De Luca Giacomo, Campochiaro Corrado, Sartorelli Silvia, De Gaspari Monica, Rizzo Stefania, Dagna Lorenzo, Basso Cristina, Gianolli Luigi, Della Bella Paolo, Sala Simone

Аннотация

BACKGROUND: 18F-fluorodeoxyglucose positron emission tomography (FDG-PET) scan has no recognized role in diagnosis, prognosis, and disease monitoring in patients with arrhythmic myocarditis.

OBJECTIVES: The purpose of this study was to investigate the value of FDG-PET scan in arrhythmic myocarditis.

METHODS: The authors enrolled 75 consecutive patients (age 47 ± 14 years, 65% men) undergoing FDG-PET scan for arrhythmic myocarditis. Myocarditis was diagnosed by endomyocardial biopsy (EMB) and, whenever applicable, cardiac magnetic resonance (CMR).

RESULTS: Indications for FDG-PET scan included either contraindication to CMR (n = 50) or mismatch between CMR and EMB (n = 25). Overall, 50 patients (67%) had positive FDG-PET. Sensitivity was 75% referring to EMB, and 73% to CMR. Specificity was 67% referring to EMB, and 59% to CMR. FDG-PET accuracy was lower in the presence of borderline myocarditis, and either late (>30 days) or on-immunosuppression FDG-PET scanning. Anteroseptal distribution pattern, found in 12 of 50 (24%) patients including 7 of 7 cardiac sarcoidosis cases, was associated with greater occurrence of ventricular arrhythmias and atrioventricular blocks in 4.2 ± 1.7 years of follow-up (10 of 12 vs 7 of 38, and 7 of 12 vs 0 of 38, respectively; both P < 0.001). In 39 patients (52%), FDG-PET was repeated by 13 ± 2 months, allowing immunosuppression withdrawal after FDG uptake normalization either by first (76%) or second reassessment (24%).

CONCLUSIONS: FDG-PET scan may be a clinically useful diagnostic technique in arrhythmic myocarditis, in particular when CMR is unsuitable because of irregular heartbeat or implantable cardioverter-defibrillator-related artifacts. Anteroseptal FDG distribution is associated with a worse arrhythmic outcome and should raise the suspicion of cardiac sarcoidosis. During follow-up, repeated FDG-PET allows myocarditis monitoring to guide immunosuppression withdrawal.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты