MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3760/cma.j.issn.0529-5815.2017.08.001

Медицинская библиотека · Zhonghua wai ke za zhi [Chinese journal of surgery] · 2017

[Pay attention to the standardized application of new techniques in surgical treatment of thyroid disease].

Tian W, Xi H Q, Wang B

СтатьяПеревод пока не подготовлен

Аннотация

The continuous development and application of new technology in thyroid surgery has promoted the rapid improvement of thyroid surgery. New technology in the field of thyroid surgery has developed rapidly. The application of neural monitoring technology has enabled the thyroid surgery to enter an accurate era. Imtraoperative neuromonitoring and continuous intraoperative neuromonitoring have made the recurrent laryngeal nerve protection more secure. Nano-carbon parathyroid gland negative imaging technology could identify parathyroid gland more precise. However, when the nano-carbon was used, the injection time, position and dosage should be grasped so as to achieve the best effect of negative imaging. Endoscopic and robotic thyroid surgery could meet the demand of cosmetic. "Treatment first, beauty second" is still the principle to be strictly followed. Do not blindly expand indications and pursue endoscopic surgery. Energy surgical instruments' update made the operation more efficient, while the instruments have some disadvantages. Thyroid surgeon must correctly understand the working principle of new energy devices and use them rationally. Through grasping the working principle and application skills of new technology in clinical work, definiting its advantages and disadvantages, adhereing to the "reasonable choice, standard application" principle, learning the pioneers' experience, the application of new thyroid diagnosis and treatment technology could be more reasonable and safe.

Для цитирования: Tian W, Xi H Q, Wang B. [Pay attention to the standardized application of new techniques in surgical treatment of thyroid disease].. Zhonghua wai ke za zhi [Chinese journal of surgery]. 2017. DOI: 10.3760/cma.j.issn.0529-5815.2017.08.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.