MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/hsr2.1714

Медицинская библиотека · Health science reports · 2023

Coronary microvascular resistance comparison of coronary arteries with and without considering vascular diameter: A retrospective, single-center study.

Muroya Takahiro, Kawano Hiroaki, Yamamoto Fumi, Maemura Koji

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND AIMS: Measurement of coronary microvascular resistance (MR) is essential for diagnosing nonocclusive coronary artery ischemia, but whether coronary branches of different diameters can be similarly assessed using hyperemic microvascular resistance index (hMVRI) calculated from average peak velocity (APV) remains unclear. We investigated the relationship between coronary arteries of different diameters and hMVRI.

METHODS

Thirty patients with suspected angina pectoris and nonobstructive coronary stenosis with fractional flow reserve >0.8 underwent evaluation of all coronary arteries using a Doppler velocity and pressure-equipped guidewire. Quantitative coronary angiography (QCA) was used to analyze vessel diameter (DQCA). Coronary blood flow (CBFQCA) was calculated as πDQCA 2/4 (0.5 × APV) and hMVRIQCA as distal coronary pressure divided by CBFQCA during maximal hyperemia.

RESULTS

The hMVRI was significantly higher for the right coronary artery than for the left anterior descending artery, but no significant differences between arteries were seen for CBFQCA and hMVRIQCA. Although the correlation between CBFQCA and APV was weak, CBFQCA divided into three groups according to DQCA showed very strong correlations with APV. Slopes of the straight line between APV and CBFQCA for small-, middle-, and large-diameter groups were 0.48, 0.30, and 0.21, respectively, with slope decreasing as diameter increased.

CONCLUSIONS

Comparative evaluation of MR in coronary branches with varying vessel diameters requires vessel diameter to be accounted for.

Для цитирования: Muroya Takahiro, Kawano Hiroaki, Yamamoto Fumi, Maemura Koji. Coronary microvascular resistance comparison of coronary arteries with and without considering vascular diameter: A retrospective, single-center study.. Health science reports. 2023. DOI: 10.1002/hsr2.1714.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.