m+Medelevator.RU
← Поиск публикаций
Clinical & experimental optometry · 2023

Ten-year outcomes following small incision lenticule extraction for up to -10Dioptres myopia.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Xia Fei, Chen Zhuoyi, Miao Huamao, Wei Ruoyan, Li Meiyan, Zhao Jing, Zhou Xingtao

Аннотация

CLINICAL RELEVANCE: More than 6 million small-incision lenticule extraction (SMILE) procedures have been performed worldwide since 2011. Therefore, its long-term safety and efficacy should be investigated.

BACKGROUND: This study aimed to evaluate 10-year refractive outcomes, corneal stability, axial length, and wavefront aberrations in patients who underwent SMILE to correct myopia.

METHODS: Thirty two patients (32 eyes) who underwent SMILE-based myopic correction. Corrected distance visual acuity, uncorrected distance visual acuity, corneal stability, axial length, and wavefront aberrations were evaluated preoperatively and at 1 month and 1, 5, and 10 years postoperatively.

RESULTS: At 10 years postoperatively, the safety and efficacy indices for the patients included in this study were 1.19 ± 0.21 and 1.04 ± 0.27, respectively. For 26 (81%) and 30 eyes (94%), correction to within ±0.50 D and ±1.00 D of the target was achieved, respectively. Over the 10-year follow-up duration, a mean -0.32 ± 0.56 D regression was observed (-0.03 ± 0.06 D/year). Relative to baseline, horizontal and vertical comas significantly increased, as did the incidence of higher-order aberrations (all P < 0.001), whereas axial length and corneal elevation remained stable during follow-up.

CONCLUSION: These results indicate that the SMILE-based correction for myopia of up to -10 Dioptres is safe, effective, and stable, with relatively constant wavefront aberrations and corneal stability over time after treatment.