MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1101/2023.02.25.529586

Медицинская библиотека · bioRxiv : the preprint server for biology · 2023

AIM (Angular Indication Measurement)- Visual Acuity: An adaptive, self-administered, and generalizable vision assessment method used to measure visual acuity.

Skerswetat Jan, He Jingyi, Shah Jay Bijesh, Aycardi Nicolas, Freeman Michelle, Bex Peter John

ПрепринтСтатьяПеревод пока не подготовлен

Аннотация

This proof-of-concept study introduces Angular Indication Measurement and applies it to VA (AIM-VA). First, we compared the ability of AIM-VA and ETDRS to detect defocus and astigmatic blur in 22 normally-sighted adults. Spherical and cylindrical lenses (±0.00D, +0.25D, +0.50D, +0.75D, +1.00D, +2.00D and +0.50D, +1.00D, +2.00D each at 0°, 90°, 135°, respectively) in the dominant eye induced blur. Second, we compared repeatability over two tests of AIM-VA and ETDRS. A 2-way-ANOVA showed a main effect for defocus-blur and test with no interaction. A 3-way-ANOVA for the astigmatism experiment revealed main effects for test type, blur, and direction and with no interactions. Planned multiple comparisons showed AIM had greater astigmatic-induced VA loss than ETDRS. Bland-Altman plots showed small bias and no systematic learning effect for either test type and improved repeatability with >2 adaptive steps for AIM-VA. AIM-VA's ability to detect defocus was comparable with that of an ETDRS letter chart and showed greater sensitivity to astigmatic blur, and AIM-VA's repeatability is comparable with ETDRS when using 2 or more adaptive steps. AIM's self-administered orientation judgment approach is generalizable to interrogate other visual functions, e.g., contrast, color, motion, stereo-vision.

Для цитирования: Skerswetat Jan, He Jingyi, Shah Jay Bijesh, Aycardi Nicolas, Freeman Michelle, Bex Peter John. AIM (Angular Indication Measurement)- Visual Acuity: An adaptive, self-administered, and generalizable vision assessment method used to measure visual acuity.. bioRxiv : the preprint server for biology. 2023. DOI: 10.1101/2023.02.25.529586.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.