m+Medelevator.RU
← Поиск публикаций
Journal of cataract and refractive surgery · 2023

Comparison of the Barrett toric calculator using measured and predicted posterior corneal astigmatism and the Kane and Abulafia-Koch calculators.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Reitblat Olga, Barnir Megiddo, Qassoom Ayat, Levy Adi, Assia Ehud I, Kleinmann Guy

Аннотация

PURPOSE: To compare the accuracy of the Barrett toric calculator with measured and predicted posterior corneal astigmatism (MPCA and PPCA, respectively), the Abulafia-Koch (AK) formula, and the toric Kane formula.

SETTING: Ein-Tal Eye Center, Tel-Aviv, Israel.

DESIGN: Retrospective cohort.

METHODS: Consecutive cases of patients who underwent uneventful cataract extraction surgery with implantation of a toric intraocular lens between March 2015 and July 2019 were retrospectively reviewed. 1 eligible eye from each patient was included. The predicted postoperative refractive astigmatism was calculated using each method and compared with the postoperative refractive astigmatism to give the prediction error.

RESULTS: 80 eyes of 80 patients were included in this study. The mean centroid and the mean and median absolute prediction errors using Kane (0.25 diopters [D] ± 0.54 @ 6 degrees, 0.50 D ± 0.31 and 0.45 D, respectively) were significantly different compared with MPCA (0.12 D ± 0.52 @ 16 degrees, P < .001, .44 D ± 0.28 and 0.36 D, P = .027, respectively), PPCA (0.09 D ± 0.49 @ 12 degrees, P < .001, .41 D ± 0.27 and 0.35 D, P < .001, respectively), and AK (0.11 D ± 0.49 @ 11 degrees, P < .001, .42 D ± 0.27 and 0.35 D, P = .004, respectively). No significant differences were found between the calculators in the predictability rates within ±0.25 D, ±0.50 D, ±0.75 D, and ±1.00 D.

CONCLUSIONS: The measured posterior corneal curvature in the Barrett calculator yielded comparable outcomes to its prediction by the Barrett and AK formulas. The Kane calculator showed a slight against-the-rule prediction error compared with the other methods, resulting in a small higher median absolute error with marginal clinical importance.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты