DOI 10.1097/j.jcrs.0000000000001178

Медицинская библиотека · Journal of cataract and refractive surgery · 2023

Comparison of the Barrett toric calculator using measured and predicted posterior corneal astigmatism and the Kane and Abulafia-Koch calculators.

Reitblat Olga, Barnir Megiddo, Qassoom Ayat, Levy Adi, Assia Ehud I, Kleinmann Guy

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the accuracy of the Barrett toric calculator with measured and predicted posterior corneal astigmatism (MPCA and PPCA, respectively), the Abulafia-Koch (AK) formula, and the toric Kane formula.

SETTING

Ein-Tal Eye Center, Tel-Aviv, Israel.

DESIGN

Retrospective cohort.

METHODS

Consecutive cases of patients who underwent uneventful cataract extraction surgery with implantation of a toric intraocular lens between March 2015 and July 2019 were retrospectively reviewed. 1 eligible eye from each patient was included. The predicted postoperative refractive astigmatism was calculated using each method and compared with the postoperative refractive astigmatism to give the prediction error.

RESULTS

80 eyes of 80 patients were included in this study. The mean centroid and the mean and median absolute prediction errors using Kane (0.25 diopters [D] ± 0.54 @ 6 degrees, 0.50 D ± 0.31 and 0.45 D, respectively) were significantly different compared with MPCA (0.12 D ± 0.52 @ 16 degrees, P < .001, .44 D ± 0.28 and 0.36 D, P = .027, respectively), PPCA (0.09 D ± 0.49 @ 12 degrees, P < .001, .41 D ± 0.27 and 0.35 D, P < .001, respectively), and AK (0.11 D ± 0.49 @ 11 degrees, P < .001, .42 D ± 0.27 and 0.35 D, P = .004, respectively). No significant differences were found between the calculators in the predictability rates within ±0.25 D, ±0.50 D, ±0.75 D, and ±1.00 D.

CONCLUSIONS

The measured posterior corneal curvature in the Barrett calculator yielded comparable outcomes to its prediction by the Barrett and AK formulas. The Kane calculator showed a slight against-the-rule prediction error compared with the other methods, resulting in a small higher median absolute error with marginal clinical importance.

Для цитирования: Reitblat Olga, Barnir Megiddo, Qassoom Ayat, Levy Adi, Assia Ehud I, Kleinmann Guy. Comparison of the Barrett toric calculator using measured and predicted posterior corneal astigmatism and the Kane and Abulafia-Koch calculators.. Journal of cataract and refractive surgery. 2023. DOI: 10.1097/j.jcrs.0000000000001178.