BMC ophthalmology · 2023
A novel surgical approach for fixation of a posterior chamber intraocular lens of Rayner 620 H with Gore-Tex suture.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Wang Tan, Chen Youxin, Lu Jun, Li Ningning, Min Hanyi
Аннотация
PURPOSE: To report a novel surgical approach for the scleral fixation of the Rayner 620 H intraocular lens (IOL) with Gore-Tex suture and its outcomes at 6 months postoperatively.
METHODS: 19 consecutive patients who underwent novel surgical approach for the scleral fixation of Rayner 620 H IOL with Gore-Tex suture at Peking Union Medical College Hospital between June 2020 and June 2021 were included. Data on best-corrected visual acuity (BCVA), spherical equivalent, total astigmatism/axis, short-term and long-term complications, and corresponding management with a follow-up of 6 months were collected.
RESULTS: Nineteen patients (11 men and 8 women) with a mean age of 62.7 ± 10.6 years were included. The median BCVA improved significantly from 0.90 ± 0.90 (Snellen 20/160) preoperatively to 0.20 ± 0.30 (Snellen 20/32) at postoperative 6 months follow-up (P < 0.001). The stratification of the accuracy of refractive outcomes was 53% of patients within ± 0.5 D and 84% of patients within ± 1.0 D of the refractive target. Corneal edema (n = 3, 16%) and increased intraocular pressure (IOP) (n = 4, 11%) were short-term complications. Long-term complications included increased IOP (n = 1, 5%), and macular edema (n = 1, 5%).
CONCLUSION: The novel surgical approach for scleral fixation of the Rayner 620 H IOL with Gore-Tex suture is a reasonable option for patients who need secondary IOL placement without adequate capsular support.
METHODS: 19 consecutive patients who underwent novel surgical approach for the scleral fixation of Rayner 620 H IOL with Gore-Tex suture at Peking Union Medical College Hospital between June 2020 and June 2021 were included. Data on best-corrected visual acuity (BCVA), spherical equivalent, total astigmatism/axis, short-term and long-term complications, and corresponding management with a follow-up of 6 months were collected.
RESULTS: Nineteen patients (11 men and 8 women) with a mean age of 62.7 ± 10.6 years were included. The median BCVA improved significantly from 0.90 ± 0.90 (Snellen 20/160) preoperatively to 0.20 ± 0.30 (Snellen 20/32) at postoperative 6 months follow-up (P < 0.001). The stratification of the accuracy of refractive outcomes was 53% of patients within ± 0.5 D and 84% of patients within ± 1.0 D of the refractive target. Corneal edema (n = 3, 16%) and increased intraocular pressure (IOP) (n = 4, 11%) were short-term complications. Long-term complications included increased IOP (n = 1, 5%), and macular edema (n = 1, 5%).
CONCLUSION: The novel surgical approach for scleral fixation of the Rayner 620 H IOL with Gore-Tex suture is a reasonable option for patients who need secondary IOL placement without adequate capsular support.