Investigation of contrast visual acuity with rigid gas permeable contact lenses after penetrating Keratoplasty.

Zhang Ju, Lin Xiao, Wang Xinhai, Cheng Zhiwei, Li Xiaoxiao, He Jicang, Shi Weiyun, Gao Hua

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

To investigate the effects of rigid gas permeable contact lens (RGP-CL) wear on contrast visual acuity in patients after penetrating keratoplasty.

METHODS

Nineteen patients (19 eyes), aged 30.45 ± 5.83 years, who had received penetrating keratoplasty and were successfully fitted with RGP-CLs at our hospital from July 2017 to June 2018 were included. Contrast visual acuities at 100%, 25%, and 10% with spectacles and RGP-CLs were analyzed using the Chi-square test. The wavefront aberrations at the anterior surface of the cornea before and 1 month after RGP-CL wear were compared using the matched sample t-test.

RESULTS

The mean best spectacle-corrected visual acuities were 0.390 ± 0.135 logMAR, 0.706 ± 0.182 logMAR, and 0.952 ± 0.223 logMAR at the 100%, 25%, and 10% contrast levels, respectively, which were significantly lower than the RGP-CL-corrected visions at the three levels (0.255 ± 0.133 logMAR, 0.488 ± 0.168 logMAR, and 0.737 ± 0.159 logMAR; all P < 0.001). The vision losses with RGP-CLs were 0.231 ± 0.099 logMAR and 0.466 ± 0.094 logMAR at the 25% and 10% contrast levels, respectively. The Zernike spherical aberration Z04 was reduced from 3.734 ± 1.061 μm to 2.622 ± 0.725 μm after wearing the RGP-CLs (P ≤ 0.001). The astigmatism parameters of Z- 22 and Z22 were also reduced from 3.761 ± 2.309 μm and 3.316 ± 2.147 μm to 2.637 ± 1.722 μm and 2.016 ± 1.184 μm, respectively (P < 0.05).

CONCLUSION

For post-keratoplasty patients, RGP-CLs can help to improve visual performance, especially low contrast visual acuity. The improvement may be related to the reduction of corneal aberrations, mainly the spherical and astigmatism aberrations.

Для цитирования: Zhang Ju, Lin Xiao, Wang Xinhai, Cheng Zhiwei, Li Xiaoxiao, He Jicang, Shi Weiyun, Gao Hua. Investigation of contrast visual acuity with rigid gas permeable contact lenses after penetrating Keratoplasty.. BMC ophthalmology. 2023. DOI: 10.1186/s12886-023-02769-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.