Refractive outcomes following bilateral implantation of a diffractive toric intraocular lens in a multisurgeon hospital setting.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Mohaseb Kam, Tischler Aron, Hall Brad, Isbister Carolyn, Godinho Derek, Goldberg Aron, Fine David
Аннотация
OBJECTIVE: To assess residual postoperative refractive astigmatism following bilateral implantation of a trifocal toric intraocular lens (IOL) in a real-world multisurgeon setting.
DESIGN: Prospective multisurgeon study (6 surgeons at 2 sites).
METHODS: Bilateral implantation of a trifocal toric IOL (AcrySof PanOptix IOL; Alcon Vision LLC, Fort Worth, TX, USA) was performed in 140 eyes of 70 patients. Patients were assessed on day 1 and 3 months postoperatively. The primary outcome measure was residual astigmatism. Secondary endpoints included absolute prediction error, IOL rotation, binocular uncorrected and distance-corrected visual acuities at near (40 cm), intermediate (60 cm), and distance (6 m) and spectacle independence evaluated with the validated Intraocular Lens Satisfaction questionnaire.
RESULTS: Mean preoperative cylinder was 1.25 ± 0.72 D and was 0.39 ± 0.28 D at 3 months postoperatively. At 3 months postoperatively, mean residual astigmatism was 0.39 ± 0.28 D (range, 0-1.25 D), and 118 eyes (84.3%) had postoperative astigmatism of 0.5 D or less. Mean absolute prediction error was 0.25 ± 0.21 D (range, 0-1.13 D), and 124 eyes (88.6%) had absolute prediction error of 0.5 D or less. At 3 months postoperatively, mean absolute rotation was 2.0 ± 2.7 degrees compared with baseline (range, 0-15 degrees), and 133 IOLs (95.0%) were within 5 degrees of the implanted axis. Additionally, 55 patients (79%) reported never or rarely using spectacles at near, 66 (94%) at intermediate, and 67 (96%) at distance.
CONCLUSIONS: The results of this study demonstrate that implantation with the PanOptix toric IOL can provide excellent refractive and visual outcomes with minimal residual astigmatism.
DESIGN: Prospective multisurgeon study (6 surgeons at 2 sites).
METHODS: Bilateral implantation of a trifocal toric IOL (AcrySof PanOptix IOL; Alcon Vision LLC, Fort Worth, TX, USA) was performed in 140 eyes of 70 patients. Patients were assessed on day 1 and 3 months postoperatively. The primary outcome measure was residual astigmatism. Secondary endpoints included absolute prediction error, IOL rotation, binocular uncorrected and distance-corrected visual acuities at near (40 cm), intermediate (60 cm), and distance (6 m) and spectacle independence evaluated with the validated Intraocular Lens Satisfaction questionnaire.
RESULTS: Mean preoperative cylinder was 1.25 ± 0.72 D and was 0.39 ± 0.28 D at 3 months postoperatively. At 3 months postoperatively, mean residual astigmatism was 0.39 ± 0.28 D (range, 0-1.25 D), and 118 eyes (84.3%) had postoperative astigmatism of 0.5 D or less. Mean absolute prediction error was 0.25 ± 0.21 D (range, 0-1.13 D), and 124 eyes (88.6%) had absolute prediction error of 0.5 D or less. At 3 months postoperatively, mean absolute rotation was 2.0 ± 2.7 degrees compared with baseline (range, 0-15 degrees), and 133 IOLs (95.0%) were within 5 degrees of the implanted axis. Additionally, 55 patients (79%) reported never or rarely using spectacles at near, 66 (94%) at intermediate, and 67 (96%) at distance.
CONCLUSIONS: The results of this study demonstrate that implantation with the PanOptix toric IOL can provide excellent refractive and visual outcomes with minimal residual astigmatism.