BACKGROUND

Utilization of the Pipeline embolization device (PED) to treat distal carotid circulation aneurysms has not been well studied.

OBJECTIVE

To report the collective experience of using PED to treat distal anterior circulation aneurysms.

METHODS

We retrospectively reviewed clinical and radiographic records of all patients who underwent Pipeline embolization of distal anterior circulation aneurysms at 10 US neurosurgical centers between 2011 and 2013.

RESULTS

Twenty-eight patients (mean age 51.7 years; 18 women) with 28 aneurysms were included in the analyses. Fifteen aneurysms were fusiform, 5 dissecting, and 8 saccular. Average aneurysm size was 12.3 mm; 7 were giant. Twenty aneurysms were located along the middle cerebral artery, 6 along the anterior cerebral artery, and 2 along the anterior communicating artery. PED deployment was successful in 27 patients, with coils utilized in 6 cases. Clinical follow-up was available for an average of 10.7 months (range 3-26). Twenty-seven patients had follow-up neurovascular imaging: 21 aneurysms had complete occlusion, 4 had residual neck filling, and 2 had residual dome filling. Periprocedural complications (<30 days) occurred in 3 patients (10.7%), including 1 case of device failure resulting in stroke. Outcomes were good (modified Rankin Scale score 0 to 2) in 27 patients (96.4%) and fair (modified Rankin Scale 3) in 1.

CONCLUSION

PED can be utilized in the treatment of distal anterior circulation aneurysms with difficult anatomy for conventional surgical or endovascular techniques. Larger-scale studies with long-term follow-up are needed to further elucidate the durability of PED treatment and its effect on perforator-rich vascular segments.

ABBREVIATIONS: ACA, anterior cerebral arteryAcomA, anterior communicating arteryDSA, digital subtraction angiographyMCA, middle cerebral arterymRS, modified Rankin scalePED, Pipeline embolization device.

Для цитирования: Lin Ning, Lanzino Giuseppe, Lopes Demetrius K, Arthur Adam S, Ogilvy Christopher S, Ecker Robert D, Dumont Travis M, Turner Raymond D, Gooch M Reid, Boulos Alan S, Kan Peter, Snyder Kenneth V, Levy Elad I, Siddiqui Adnan H. Treatment of Distal Anterior Circulation Aneurysms With the Pipeline Embolization Device: A US Multicenter Experience.. Neurosurgery. 2016. DOI: 10.1227/neu.0000000000001117.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.