MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1088/1361-6560/ae9711

Медицинская библиотека · Physics in medicine and biology · 2026

Machine-learning-based source localization for an intraoperative forceps-type positron emission counter.

Ohashi Ryotaro, Takyu Sodai, Ito Shigeki, Takahashi Miwako, Yamaya Taiga

СтатьяПеревод пока не подготовлен

Аннотация

Objective.Intraoperative identification of metastatic lymph nodes in esophageal cancer surgery could enable more selective lymph-node dissection. A forceps-type positron emission counter (PEC)-a compact coincidence detector designed to intraoperatively quantifyF-FDG uptake in individual lymph nodes through standard laparoscopic trocars-requires the radioactive source to be centered within its field of view for accurate quantification, yet current hardware provides no positional feedback.Approach.A position-sensitive detector was designed by segmenting the conventional monolithic scintillator into acrystal array. A pair of such detectors provides 16 coincidence count values, which serve as input to a machine-learning model that outputs the three-dimensional center of gravity (CoG) of the source with an intrinsic uncertainty indicator. Training data were generated by Monte Carlo simulations using a sensitivity-map superposition method with random source distributions varying in size, shape, position, and activity concentration.Main results.The CoG was estimated with errors of approximately 0.34-0.42 mm per axis (Euclidean mean absolute error (MAE) 0.74 mm). In simulation, repositioning based on the estimated CoG reduced measurement variability (percent standard deviation) from 52% to 15%. A prototype experiment achieved Euclidean MAE of 1.33 mm at 100 coincidence counts.Significance.These results demonstrate that machine-learning-based source localization has substantial potential to enhance the quantitative accuracy and reliability of forceps-type PEC systems for intraoperative lymph node assessment.

Для цитирования: Ohashi Ryotaro, Takyu Sodai, Ito Shigeki, Takahashi Miwako, Yamaya Taiga. Machine-learning-based source localization for an intraoperative forceps-type positron emission counter.. Physics in medicine and biology. 2026. DOI: 10.1088/1361-6560/ae9711.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.