MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-021-03154-6

Медицинская библиотека · Scientific reports · 2021

Calibration of two validated SARS-CoV-2 pseudovirus neutralization assays for COVID-19 vaccine evaluation.

Huang Yunda, Borisov Oleg, Kee Jia Jin, Carpp Lindsay N, Wrin Terri, Cai Suqin, Sarzotti-Kelsoe Marcella, McDanal Charlene, Eaton Amanda, Pajon Rolando, Hural John, Posavad Christine M, Gill Katherine, Karuna Shelly, Corey Lawrence, McElrath M Juliana, Gilbert Peter B, Petropoulos Christos J, Montefiori David C

Сравнительное исследованиеСтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Vaccine-induced neutralizing antibodies (nAbs) are key biomarkers considered to be associated with vaccine efficacy. In United States government-sponsored phase 3 efficacy trials of COVID-19 vaccines, nAbs are measured by two different validated pseudovirus-based SARS-CoV-2 neutralization assays, with each trial using one of the two assays. Here we describe and compare the nAb titers obtained in the two assays. We observe that one assay consistently yielded higher nAb titers than the other when both assays were performed on the World Health Organization's anti-SARS-CoV-2 immunoglobulin International Standard, COVID-19 convalescent sera, and mRNA-1273 vaccinee sera. To overcome the challenge this difference in readout poses in comparing/combining data from the two assays, we evaluate three calibration approaches and show that readouts from the two assays can be calibrated to a common scale. These results may aid decision-making based on data from these assays for the evaluation and licensure of new or adapted COVID-19 vaccines.

Для цитирования: Huang Yunda, Borisov Oleg, Kee Jia Jin, Carpp Lindsay N, Wrin Terri, Cai Suqin, Sarzotti-Kelsoe Marcella, McDanal Charlene, Eaton Amanda, Pajon Rolando, Hural John, Posavad Christine M, Gill Katherine, Karuna Shelly, Corey Lawrence, McElrath M Juliana, Gilbert Peter B, Petropoulos Christos J, Montefiori David C. Calibration of two validated SARS-CoV-2 pseudovirus neutralization assays for COVID-19 vaccine evaluation.. Scientific reports. 2021. DOI: 10.1038/s41598-021-03154-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.