m+Medelevator.RU
← Поиск публикаций
The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2005

The 6-minute walk test does not reliably detect changes in functional capacity of patients awaiting cardiac transplantation.

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Cheetham Craig, Taylor Roger, Burke Valerie, O'Driscoll Gerard, Green Daniel J

Аннотация

BACKGROUND: Peak oxygen consumption (Vo(2)peak) is a strong independent predictor of prognosis in patients with severe chronic heart failure (CHF) and is used to guide optimal timing of transplantation. However, its assessment is relatively expensive and time-consuming and requires sophisticated equipment and highly trained personnel. The purpose of this study was to determine whether changes in 6-minute walk test (6WT) distance, a simple, inexpensive potential alternative measure of functional capacity, can predict changes in Vo(2)peak in patients with severe CHF.

METHODS: Sixteen subjects (ejection fraction 23+/-2%, Vo(2)peak 16.2+/-1.1 ml kg (-1)min(-1)) underwent repeated 6WT and Vo(2)peak assessments that included familiarization and 4 serial measures, 6 weeks apart (baseline and at Weeks 6, 12 and 18). Analysis compared baseline performance with each subsequent testing occasion.

RESULTS: At baseline, mean (+/-SE) VO(2)peak was 16.3+/-1.1 ml kg(-1) min(-1) and 6WT distance was 458+/-21 m. 6WT and Vo(2)peak were strongly correlated at all timepoints (average r=0.82; all p<0.05). However, mixed model analysis, assessing the capacity of the changes seen in 6WT to predict changes in Vo(2)peak, showed no statistical significance (F=0.11; p=0.74).

CONCLUSIONS: The 6WT is commonly used to assess functional capacity in patients with heart failure. This study demonstrates that, despite a strong cross-sectional correlation with Vo(2)peak, changes in the 6WT are not a reliable predictor of changes in Vo(2)peak within patients. Therefore, the 6WT has limited utility as a serial measure to assess changes in the clinical status of patients with severe heart failure.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты