MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s1053-2498(02)00570-3

Медицинская библиотека · The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2003

Morbidity and mortality of UNOS status 1B cardiac transplant candidates at home.

Lang Chim C, Hankins Shelley, Hauff Helen, Maybaum Simon, Edwards Niloo, Mancini Donna M

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

On January 20, 1999, UNOS listing regulations changed, allowing stable patients on inotropic support (Status IB) to be discharged home until cardiac transplant. The outcome, morbidity and cost savings of this new strategy has not been evaluated.

METHODS

From 1/20/99 through 1/1/01, 155 patients were classified as UNOS Status 1B at our institution; 64 patients were never discharged and 91 were discharged home. Criteria for discharge were hemodynamic stability on low-dose, single-agent parenteral inotropic infusion, defined as dobutamine at a dose <7.5 microg/kg/min or milrinone <0.5 microg/kg/min. Data on re-admissions were collected prospectively. The frequency of complex ventricular arrhythmias was evaluated in a sub-group discharged with external or internal cardiodefibrillators (n = 38).

RESULTS

Total Status I time to transplant for the 91 discharged patients was 139 +/- 91 days, with 87 +/- 67 days spent at home. Inpatient time to transplant was still high, with a mean of 51 +/- 45 days. The in-hospital time was comparable to that of the 64 patients who were never discharged (51 +/- 41 days). Fifty-nine percent of discharged patients were re-admitted, with 37% of patients requiring more than 1 admission. Sixty-six percent of admissions were for worsening heart failure (CHF), and 34% for infection or occlusion of the indwelling intravenous line. No significant arrhythmic events were recorded in the 38 patients who had internal or external cardiodefibrillators. Two patients died suddenly at home. One patient had declined to wear the external cardiodefibrillator. The other patient was not wearing the defibrillator at the time of the event, and in 634 hours of previous monitoring he had had no events.

CONCLUSIONS

In UNOS Status 1B patients awaiting cardiac transplant on home inotropic therapy, mortality remains low but the re-admission rate was high. There appeared to be a low incidence of complex ventricular arrhythmias.

Для цитирования: Lang Chim C, Hankins Shelley, Hauff Helen, Maybaum Simon, Edwards Niloo, Mancini Donna M. Morbidity and mortality of UNOS status 1B cardiac transplant candidates at home.. The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation. 2003. DOI: 10.1016/s1053-2498(02)00570-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.