The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc · 2002

Visual performance of a multi-zone bifocal and a progressive multifocal contact lens.

Клиническое исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Guillon Michel, Maissa Cecile, Cooper Philip, Girard-Claudon Karine, Poling Timothy R

Аннотация

PURPOSE: This study measured the relative visual performance of two planned-replacement soft contact lenses for presbyopic correction: a multi-zone bifocal (ACUVUE, Johnson & Johnson Vision Care, Jacksonville, FL) contact lens and a progressive multifocal (Focus Progressives, CIBA Vision, Duluth, GA) contact lens.

METHODS: This was a randomized, double-masked, non-dispensing cross-over study. Visual performance was evaluated by log of minimal angle of resolution (LogMAR) measurement of visual acuity (VA) under a representative range of luminances (distance 250 candela[cd]/m2 and 2.5 cd/m2, near 250 cd/m2 and 50 cd/m2) and contrasts (90% and 10%). The 45 presbyopic subjects were equally distributed in three subgroups according to spectacle addition: low presbyopia (+0.75D to +1.25D); medium presbyopia (+ 1.50D to + 1.75D); and high presbyopia (+2.00 to +2.50D).

RESULTS: Statistically significant differences were found in overall distance VA (P<0.001; average of four luminance-contrast combinations) and low-luminance distance VA (P=0.004), which, in both cases, favored the multi-zone bifocal lens design. For low presbyopes, the multi-zone bifocal design produced a significantly better visual performance (P=0.004) than did the progressive multifocal. Overall near VA was also significantly better (P<0.001) with the multi-zone bifocal lens. Differences in near VA were particularly marked in high-luminance conditions (high and low contrasts combined) and were statistically significant for all three presbyopic subgroups.

CONCLUSIONS: Visual acuity performance with the multi-zone bifocal was superior overall to that achieved with the progressive multifocal design. This study suggests that having only one addition is detrimental to performance with the progressive multifocal lens, particularly for low presbyopes.