Journal of magnetic resonance imaging : JMRI · 2002
Refractive anomalies and visual activation in functional magnetic resonance imaging (fMRI): a versatile and low-cost MR-compatible device to correct a potential confound.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Elbel Gregor-K, Kaufmann Christian, Schaefers Stefan, Buser Anne, Auer Dorothee P
Аннотация
PURPOSE: To develop a magnetic resonance (MR)-compatible, versatile, easy-to-use, and low-cost device for refractive correction.
MATERIALS AND METHODS: We retrospectively evaluated the application and practicability of the refractive correction in 110 subjects who had participated in various functional MR imaging (fMRI) studies with complex visual stimulation paradigms since the introduction of the MR-compatible lens frame at our site. The subjects consisted of 31 patients with Parkinson's disease (age range, 40-85; mean age, 63.2 years) and 79 healthy volunteers (age range, 18-79; mean age, 46.7 years).
RESULTS: In volunteers, experimentally induced myopia caused a substantial (>20%) reduction of the blood oxygenation level dependent (BOLD) response to a flickering dartboard.
CONCLUSION: Refractive errors (and the resulting optical blur) may play a nonnegligible role as a possible interfering factor in fMRI experiments with visual stimuli. The MR-compatible frame (fitted with appropriate lenses) used in this study affords full refractive correction at reasonable cost and preparation time.
MATERIALS AND METHODS: We retrospectively evaluated the application and practicability of the refractive correction in 110 subjects who had participated in various functional MR imaging (fMRI) studies with complex visual stimulation paradigms since the introduction of the MR-compatible lens frame at our site. The subjects consisted of 31 patients with Parkinson's disease (age range, 40-85; mean age, 63.2 years) and 79 healthy volunteers (age range, 18-79; mean age, 46.7 years).
RESULTS: In volunteers, experimentally induced myopia caused a substantial (>20%) reduction of the blood oxygenation level dependent (BOLD) response to a flickering dartboard.
CONCLUSION: Refractive errors (and the resulting optical blur) may play a nonnegligible role as a possible interfering factor in fMRI experiments with visual stimuli. The MR-compatible frame (fitted with appropriate lenses) used in this study affords full refractive correction at reasonable cost and preparation time.