BACKGROUND

Ensuring coronary access is essential for lifetime management after transcatheter aortic valve replacement (TAVR). However, the data on coronary alignment using the latest supra-annular (SA) and intra-annular (IA) self-expandable valves (SEV) are limited.

AIMS: This study evaluated coronary alignment after TAVR using SA-SEV and IA-SEV using post-procedural CT images.

METHODS

This retrospective study analyzed TAVR cases using the latest SA-SEV (n = 250) and IA-SEV (n = 152). Coronary overlap (CO) was assessed by measuring the angle between the neo-commissure and coronary ostium. Coronary geometry was evaluated by the vertical distance from the coronary ostium to top of the outer skirt and the horizontal distance from the ostium to the transcatheter heart valve (THV) frame.

RESULTS

The SA-SEV was associated with significantly lower rates of severe CO than the IA-SEV in both the left (LCA) (10% vs. 42%) and right coronary arteries (RCA) (12% vs. 34%). The vertical distance from the coronary ostium to the outer skirt was shorter in SA-SEV than in IA-SEV for both arteries (LCA: 3.3 mm vs. 8.0 mm; RCA: 4.4 mm vs. 9.0 mm). Conversely, SA-SEV demonstrated a wider horizontal distance between the coronary ostium and THV frame than IA-SEV (LCA: 4.8 mm vs. 3.8 mm; RCA: 5.4 mm vs. 4.4 mm).

CONCLUSIONS

CO and ostial geometry relative to the THV frame differed significantly between the two SEV platforms. Balancing these anatomic and device-specific factors may be essential to ensure future coronary access following TAVR.

Для цитирования: Hirofumi Hioki, Masanori Yamamoto, Tomoki Ochiai, Kenichi Ishizu, Tetsuro Shimura, Tatsuya Tsunaki, Fumiaki Yashima, Shinichi Shirai, Gaku Nakazawa, Masahiko Noguchi, Yohei Ohno, Hidetaka Nishina, Daisuke Hachinohe, Toshiaki Otsuka, Masahiko Asami, Kentaro Hayashida, OCEAN‐TAVI investigators. Differences in Coronary Alignment Between Evolut FX and Navitor Valves.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2025. DOI: 10.1002/ccd.70062.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.