m+Medelevator.RU
← Поиск публикаций
Cardiovascular intervention and therapeutics · 2025

Impact of aortic angulation on outcomes in transcatheter aortic valve replacement with balloon-expandable and self-expanding valves: a systematic review and meta-analysis.

СтатьяМетаанализСистематический обзорНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Khalefa Basma Badrawy, Gonnah Ahmed Reda, Yassin Mazen Negmeldin Aly, Fayed Hossam, Arnaout Moumen, Elkholy Mohamed Karam Allah, Ramadan Mohamed, Elettreby Abdelrahman Mohammed, Dway Ali, Eldeeb Hatem, Abujabal Abdullah Saeed, Roberts David Hesketh

Аннотация

High aortic angulation (AA) can pose significant challenges during TAVR. This meta-analysis determines the impact of a horizontal aorta on TAVR outcomes with balloon-expandable (BEV) and self-expanding valves (SEVs). A comprehensive search was conducted from inception to June 2024. Thirteen observational studies assessing the impact of aortic angulation in patients undergoing TAVR replacement were included. The pooled results indicated that short-term mortality was significantly lower in patients with a non-horizontal aorta (RR = 0.76; 95% CI 0.62-0.95, P = 0.01). Subgroup analysis displayed that BEVs had a lower short-term mortality with a horizontal aorta than SEVs. The incidence of stroke was not significantly affected by aortic angulation with either valve type. However, the overall risk of permanent pacemaker implantation was lower in patients with a non-horizontal aorta for both valve types. Paravalvular regurgitation was also reduced in the non-horizontal aorta group, with no difference between aortic angulations in patients with BEVs. In contrast, SEVs favored a non-horizontal aorta in reducing paravalvular leak (RR = 0.66; 95% CI 0.46-0.94, P = 0.02). Both BEVs and SEVs show better results in patients with lower aortic root angulation. The increased incidence of conduction abnormalities and PPI rates with both valve types in patients with horizontal aorta is a concern. BEVs could be potentially used preferentially to SEVs in patients with a horizontal aorta as there was no difference between horizontal and non-horizontal aorta groups regarding short-term mortality, moderate-to-severe paravalvular leak, and need for a second valve.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты