Correlation between insertion torque value and bone density in D3 and D4 bone following photobiomodulation: a randomised interventional study.
Аннотация
BACKGROUND
This study aimed to assess the correlation between insertion torque values and bone density measured via CBCT in D3 and D4 bone types after photobiomodulation (PBM) therapy. MATERIALS AND
METHODS
108 partially edentulous patients were divided into six groups based on PBM therapy type and bone classification. Insertion torque values were recorded during implant placement, and bone density was assessed via CBCT.
RESULTS
Statistically significant positive correlations were observed between bone density and insertion torque in all regions (cervical, middle, apical) for both D3 and D4 bone types (Spearman’s rho ≥ 0.951, p < 0.01).
CONCLUSION
Bone density correlates strongly with insertion torque values in both D3 and D4 bone following PBM therapy, suggesting its potential predictive value for implant primary stability. CLINICAL SIGNIFICANCE: With the findings of the study, CBCT can be used as a predictive tool for assessing the implant stability and also advocates the use of PBM as an adjunct to improve primary implant stability. CTRI: CTRI/2022/04/042033 dated 8/02/2022.