DOI 10.1016/j.jcrs.2016.09.016
Objective evaluation of negative dysphotopsia with Goldmann kinetic perimetry.
Аннотация
PURPOSE: To compare the extension of peripheral visual fields in phakic and pseudophakic patients and to evaluate whether Goldmann kinetic perimetry can be used as an objective measure of negative dysphotopsia.
SETTING
University Eye Clinic, Maastricht University Medical Centre, Maastricht, the Netherlands.
DESIGN
Prospective and case-control study.
METHODS
Kinetic perimetry was performed with V4e and I4e stimuli. Visual fields were assessed in the following 4 quadrants: superior temporal, superior nasal, inferior temporal, and inferior nasal. In the control group, patients were evaluated before and 1 month after cataract surgery. Biometric and perimetric data in the control group were compared with data in the patients with negative dysphotopsia (study group).
RESULTS
Each group comprised 10 patients. In the control group, the extension of visual field did not change after surgery. Patients in the study group had a significantly shorter axial length and higher intraocular lens powers than those in the control group. The inferior temporal and inferior nasal quadrants were, respectively, 10 degrees and 6 degrees (P < .05) smaller in the study group than in the control group. In 3 patients with negative dysphotopsia, a shadow was drawn in the superior temporal and the inferior temporal quadrants during perimetry and the position of this shadow matched their subjective description of negative dysphotopsia.
CONCLUSIONS
The peripheral visual field did not change after cataract surgery in patients without negative dysphotopsia. Kinetic perimetry can be used for objective evaluation of patients with negative dysphotopsia because these patients had constricted peripheral visual fields or a relative temporal scotoma corresponding to the position of the shadow.
FINANCIAL DISCLOSURE: Proprietary or commercial disclosures are listed after the references.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.