DOI 10.1016/j.jcrs.2016.08.019
Neodymium:YAG capsulotomy rates associated with femtosecond laser-assisted versus manual cataract surgery.
Аннотация
PURPOSE: To compare the neodymium:YAG posterior capsulotomy rates after cataract surgery performed using a femtosecond laser system versus manual techniques.
SETTING
Pacific Hills Surgery Center, Laguna Hills, and La Veta Surgery Center, Orange, California, USA.
DESIGN
Retrospective case study.
METHODS
After surgeries were completed between August 2011 and August 2014. A corrected distance visual acuity (CDVA) of 20/25 or better 1 to 3 months after surgery was identified in a chart review and analyzed. Intraocular lens (IOL) type and power were recorded. Capsulotomies were recorded with the date of the procedure and the precapsulotomy CDVA. Capsulotomy rates related to manual capsulorhexis and capsulorhexis with a femtosecond laser system were compared, with consideration of IOL design and material.
RESULTS
There was no statistically significant difference in posterior capsule opacification grade between surgery groups (P = .13). Capsulotomy rates were significantly lower in the femtosecond laser-assisted cataract surgery group than in the manual group (P = .04). The time between surgery and capsulotomy was statistically significantly lower in the femtosecond laser-assisted cataract surgery group (P < .01), which appeared to be a function of the higher ratio of multifocal IOLs in that group. There was a lower overall capsulotomy rate with hydrophobic acrylic IOL material than with hydrophilic IOL material.
CONCLUSIONS
Neodymium:YAG capsulotomy rates were lower with femtosecond laser-assisted cataract surgery than with manual cataract surgery. The differences were more apparent in IOL material and design groups in which overall capsulotomy rates were lower.
FINANCIAL DISCLOSURE: None of the authors has a financial or proprietary interest in any material or method mentioned.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.