MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1167/tvst.5.5.13

Медицинская библиотека · Translational vision science & technology · 2016

Psychophysical Vision Simulation of Diffractive Bifocal and Trifocal Intraocular Lenses.

Brezna Wolfgang, Lux Kirsten, Dragostinoff Nikolaus, Krutzler Christian, Plank Nicole, Tobisch Rainer, Boltz Agnes, Garhöfer Gerhard, Told Reinhard, Witkowska Katarzyna, Schmetterer Leopold

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The visual performance of monofocal, bifocal, and trifocal intraocular lenses was evaluated by human individuals using a vision simulator device. This allowed investigation of the visual impression after cataract surgery, without the need actually to implant the lenses.

METHODS

The randomized, double-masked, three-way cross-over study was conducted on 60 healthy male and female subjects aged between 18 and 35 years. Visual acuity (Early Treatment Diabetic Retinopathy Study; ETDRS) and contrast sensitivity tests (Pelli-Robson) under different lighting conditions (luminosities from 0.14-55 cd/m2, mesopic to photopic) were performed at different distances.

RESULTS

Visual acuity tests showed no difference for corrected distance visual acuity data of bi- and trifocal lens prototypes (P = 0.851), but better results for the trifocal than for the bifocal lenses at distance corrected intermediate (P = 0.021) and distance corrected near visual acuity (P = 0.044). Contrast sensitivity showed no differences between bifocal and trifocal lenses at the distant (P = 0.984) and at the near position (P = 0.925), but better results for the trifocal lens at the intermediate position (P = 0.043). Visual acuity and contrast sensitivity showed a strong dependence on luminosity (P < 0.001).

CONCLUSIONS

At all investigated distances and all lighting conditions, the trifocal lens prototype often performed better, but never worse than the bifocal lens prototype.

TRANSLATIONAL RELEVANCE: The vision simulator can fill the gap between preclinical lens development and implantation studies by providing information of the perceived vision quality after cataract surgery without implantation. This can reduce implantation risks and promotes the development of new lens concepts due to the cost effective test procedure.

Для цитирования: Brezna Wolfgang, Lux Kirsten, Dragostinoff Nikolaus, Krutzler Christian, Plank Nicole, Tobisch Rainer, Boltz Agnes, Garhöfer Gerhard, Told Reinhard, Witkowska Katarzyna, Schmetterer Leopold. Psychophysical Vision Simulation of Diffractive Bifocal and Trifocal Intraocular Lenses.. Translational vision science & technology. 2016. DOI: 10.1167/tvst.5.5.13.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.