MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2016.06.029

Медицинская библиотека · Journal of cataract and refractive surgery · 2016

Comparison of 9 intraocular lens power calculation formulas.

Cooke David L, Cooke Timothy L

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the accuracy of 9 intraocular lens (IOL) calculation formulas using 2 optical biometers.

SETTING

Private practice, Saint Joseph, Michigan, USA.

DESIGN

Retrospective consecutive case series.

METHODS

Nine IOL power formula predictions with observed refractions after cataract surgery were compared using 1 IOL platform. The performance of each formula was ranked for accuracy by machine and by axial length (AL). The Olsen was further divided by a preinstalled version (OlsenOLCR) and a purchased version (OlsenStandalone). The Holladay 2 was divided by whether a refraction was entered (Holladay 2PreSurgRef) or not (Holladay 2NoRef). The OLCR device used in the study was the Lenstar L5 900 and the PCI device, the IOLMaster.

RESULTS

The formulas were ranked by the standard deviation of the prediction error (optical low-coherence reflectometry [OLCR], partial coherence interferometry [PCI]) as follows: OlsenStandalone (0.361, 0.446), Barrett Universal II (0.365, 0.387), OlsenOLCR (0.378, not applicable), Haigis (0.393, 0.401), T2 (0.397, 0.404), Super Formula (0.403, 0.410), Holladay 2NoRef (0.404, 0.417), Holladay 1 (0.408, 0.414), Holladay 2PreSurgRef (0.423, 0.432), Hoffer Q (0.428, 0.432), and SRK/T (0.433, 0.44).

CONCLUSIONS

The formulas gave different results depending on which machine measurements were used. The Olsen formula was the most accurate with OLCR measurements, significantly better than the best formula with PCI measurements. The Olsen was better, regardless of AL. If only PCI measurements (without lens thickness) were available, the Barrett Universal II performed the best and the Olsen formula performed the worst. The preinstalled version of Olsen was not as good as the standalone version. The Holladay 2 formula performed better when the preoperative refraction was excluded.

FINANCIAL DISCLOSURE: Neither author has a financial or proprietary interest in any material or method mentioned.

Для цитирования: Cooke David L, Cooke Timothy L. Comparison of 9 intraocular lens power calculation formulas.. Journal of cataract and refractive surgery. 2016. DOI: 10.1016/j.jcrs.2016.06.029.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.