PURPOSE: To compare distant and near visual function after cataract surgery with implantation of Crystalens HD or Tek-Clear as accommodating intraocular lenses (IOLs), versus SA60AT as a standard IOL.

METHODS

The study included 62 eyes of 58 patients divided into three groups using three different IOLs: Crystalens HD (Bausch and Lomb, NY, USA), Tek-Clear (Tekia, CA, USA) and SA60AT (Alcon, TX, USA) were implanted in 23, 14 and 25 eyes, respectively. Corrected distant visual acuity (CDVA), uncorrected and distance corrected near visual acuities (UCNVA and DCNVA), near point of accommodation (NPA), spectacle freedom and patient satisfaction were assessed six months postoperatively and compared between the three groups.

RESULTS

After 6 months, all patients showed significant improvement in CDVA with no significant difference among the study groups. However, UCNVA and DCNVA were significantly better in patients implanted with accommodating IOLs. NPA was closest in the Crystalens HD group, followed by Tek-Clear and monofocal SA60AT (P < 0.001). Patients with accommodating IOLs were more likely to become spectacle free and satisfied with their near vision as compared to subjects receiving a monofocal IOL.

CONCLUSIONS

Accommodating IOLs (Crystalens HD and Tek-Clear) effectively reduce the necessity for spectacles after cataract surgery.

Для цитирования: Sadoughi Mohammad Mehdi, Einollahi Bahram, Roshandel Danial, Sarimohammadli Mohammad, Feizi Sepehr. Visual and Refractive Outcomes of Phacoemulsification with Implantation of Accommodating versus Standard Monofocal Intraocular Lenses.. Journal of ophthalmic & vision research. 2015. DOI: 10.4103/2008-322x.176896.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.