Long-term changes in intraocular lens position and corneal curvature after cataract surgery and their effect on refraction.

Klijn Stijn, Sicam Victor Arni D P, Reus Nicolaas J

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the role of intraocular lens (IOL) position shift and changes in corneal curvature on long-term refractive shift after cataract surgery.

SETTING

Rotterdam Ophthalmic Institute, Rotterdam, the Netherlands.

DESIGN

Prospective cohort study.

METHODS

Patients who had routine cataract surgery with implantation of a hydrophobic acrylic 1-piece IOL (Acrysof SA60AT) in the capsular bag were enrolled. Measurements were performed preoperatively and 1 month, 3 months, and 1 year postoperatively. Refraction was measured with the ARK-530A autorefractor. The IOL position and corneal curvature were measured with the Lenstar LS-900 biometer. The refractive effect of changes in IOL position and corneal curvature was calculated with a Gaussian optics-based thin-lens formula and correlated with the measured refractive shift.

RESULTS

The study group comprised 59 eyes of 59 patients. The median measured absolute refractive change was 0.25 diopter (D). The IOL position showed a statistically significant mean posterior shift of 0.033 mm ± 0.060 (SD) between 1 month and 1 year postoperatively (P < .01), of which the median calculated absolute refractive effect was 0.05 D. This did not correlate with the measured refractive shift (Pearson r = 0.10, P = .46). Natural fluctuations in corneal curvature caused a median calculated absolute refractive effect of 0.17 D, which correlated well with the measured refractive shift (Pearson r = .55, P < .001).

CONCLUSIONS

Long-term changes in refraction after cataract surgery resulted from natural fluctuations in corneal curvature rather than from IOL position shift. These fluctuations limit the accuracy with which the refractive outcome can be planned.

FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.

Для цитирования: Klijn Stijn, Sicam Victor Arni D P, Reus Nicolaas J. Long-term changes in intraocular lens position and corneal curvature after cataract surgery and their effect on refraction.. Journal of cataract and refractive surgery. 2016. DOI: 10.1016/j.jcrs.2015.08.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.